Lighting the Side Burner

The side burner has a separate ignition system from the main cooking box.

DANGER

Failure to open the lid while igniting the side burner, or not waiting 5 minutes to allow the gas to clear if the side burner does not light, may result in an explosive flame-up which can cause serious bodily injury or death.

Lighting only the side burner.

1)Open the side burner lid.

2)Check that the fuel gauge reads more than “E”.

3)Check that the side burner valve is turned OFF. (Push each knob down and turn clockwise to ensure they are in the off position.), and all main burner control valves are OFF (push down and turn clockwise).

4)Turn the LP tank valve on (turn clockwise).

5)Push down and turn the side burner control valve to HI.

6)Push the side burner igniter button several times so it clicks each time.

1

5

3

6

CAUTION: Side burner flame may be difficult to see on a bright sunny day.

WARNING: If the side burner does not light:

1)Turn OFF the side burner control valve.

2)Wait 5 minutes to let the gas clear before you try again or try to light with a match.

Lighting the side burner if the main burners are lit.

1)Open the side burner lid.

2)Push down and turn the side burner control to HI.

3)Press the side burner igniter button several times so it clicks each time.

1

2

3

CAUTION: Side burner flame may be difficult to see on a bright sunny day.

WARNING: If the side burner does not light:

1)Turn OFF the side burner control valve.

2)Wait 5 minutes to let the gas clear before you try again or try to light with a match.

D-3

Page 29
Image 29
Weber SILVERC GENESIS Gas Grill, 55054 0100 manual Lighting the Side Burner, Lighting only the side burner