Weil-McLain 550-100-067/0608 manual Prevent combustion air contamination

Models: 550-100-067/0608

1 12
Download 12 pages 36.81 Kb
Page 4
Image 4
Prevent combustion air contamination

Manual backgroundManual backgroundManual backgroundgas-fired water boiler — User’s Information Manual

Prevent combustion air contamination

If the boiler combustion air inlet is located in any area likely to cause contamination, or if products which would contaminate the air cannot be removed, you must have the combustion air and vent re-piped and terminated to another location. Contaminated combustion air will damage the boiler, resulting in pos- sible severe personal injury, death or substantial property damage.

Do not operate an Ultra boiler if its combustion air inlet is located in a laundry room or pool facility, for example. These areas will always contain hazardous contaminants.

Pool and laundry products and common household and hobby products often contain fluorine or chlorine compounds. When these chemicals pass through the boiler, they can form strong acids. The acid can eat through the boiler wall, causing serious damage and presenting a possible threat of flue gas spillage or boiler water leakage into the building.

Please read the information listed below. If contaminating chemicals will be present near the location of the boiler combustion air inlet, have your installer pipe the boiler combustion air and vent to another location, per the Boiler manual.

4

Part number 550-100-067/0608

Page 4
Image 4
Weil-McLain 550-100-067/0608 manual Prevent combustion air contamination, gas-firedwater boiler - User’s Information Manual