❏End-of-season shutdown . . . . . . . .

CGa,CGi,CGs,EG,EGH,LGB,PEG,PFGBoilers

End-of-season shutdown . . . . . . . .

Follow boiler shutdown procedure

1.Follow “TO TURN OFF GAS TO APPLIANCE” on the Lighting/Operating instructions on the inside of the jacket panel. You will also find these instructions on pages 13 through 22 of this manual.

Use the Lighting/Operating instruction for the gas valve model installed on the boiler.

2.Do not drain system unless exposure to freezing temperatures will occur.

3.Do not drain the system if it is filled with an antifreeze solution.

4.Do not shut down boilers used for domestic water heating. They must operate year-round.

Propane gas odorant

Propane boilers only — Your propane supplier mixes an odorant with the propane to make its presence detect- able. In some instances, the odorant can fade and the gas may no longer have an odor.

Propane gas can accumulate at floor level. Smell near the floor for the gas odorant or any unusual odor. If you suspect a leak, do not attempt to light the pilot.

Use caution when attempting to light the propane pilot. This should be done by a qualified service techni- cian, particularly if pilot outages are common.

Periodically check the odorant level of your gas.

Inspect boiler and system at least yearly to make sure all gas piping is leak-tight.

Consult your propane supplier regarding installation of a gas leak detector. There are some products on the market intended for this purpose. Your supplier may be able to suggest an appropriate device.

Table 2
Lighting / Operating instruction guide

Lighting instructions

Use Table 2 below to locate the correct Lighting/Operating instruction for the gas valve model installed on your boiler.

Standing pilot

Models

Page

Spark-ignited pilot

Models

Page

 

 

 

 

CGa-25CGa-8

 

 

 

 

 

EG-30EG-75

16

 

 

 

Honeywell VR8204/VR8304

PEG-30PEG-55

 

CGa-25CGa-8

 

 

Honeywell VR8200/VR8300

13

 

PFG-5

 

EG-30EG-65

 

 

 

 

CGi, CGs

21

 

PEG-30PEG-55

 

 

 

 

 

 

CGa-25CGa-6

17

 

 

 

 

EG-30EG-50

 

 

 

White-Rodgers 36E

PEG-30PEG-50

 

Robertshaw 7200

CGa-25CGa-6

14

CGi

21

 

EG-30EG-50

 

 

CGs

 

PEG-30PEG-50

 

 

 

 

 

 

 

 

 

 

 

 

CGa-7,CGa-8

18

 

 

 

White-Rodgers 36C

EG-55EG-75

 

 

 

PEG-55,PFG-5

 

 

 

 

 

 

 

 

 

 

 

 

 

EG-75

 

 

CGi, CGs

21

Robertshaw 700DERHC

15

 

CGa-25CGa-6

 

 

 

EGH-85,EGH-95

Robertshaw 7200

19

EG-30EG-50

 

PFG-6,PFG-7

 

 

 

 

PEG-30PEG-50

 

 

 

 

 

 

 

 

 

Robertshaw 7000 DERHC

EGH-85EGH-125

20

 

 

 

PFG-6PFG-8

 

 

 

 

 

 

 

 

--

LGB

22

 

 

 

 

 

 

12

Part Number 550-110-592/1099

Page 12
Image 12
Weil-McLain CGa manual Lighting instructions, End-of-seasonshutdown, Follow boiler shutdown procedure, Propane gas odorant