•Standing pilot

CGa,CGi,CGs,EG,EGH,LGB,PEG,PFGBoilers

Lighting instructions

Standing pilot

Gas valve Robertshaw 7200

CGa-25 to CGa-6, EG-30 to EG-50, PEG-30 to PEG-50

FORYOUR SAFETY READ BEFORE LIGHTING

If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.

A.This appliance has a pilot, which must be lighted by hand. When lighting the pilot, follow these instructions exactly.

B.Before LIGHTING, smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor. See below.

C.Use only your hand to depress the selector arm. Never use tools. If the selector arm will not move by hand, don't try to repair it, call a qualified service technician. Force or attempted repair may result in a fire or explosion.

D.Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control, which has been under water.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electric switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

LIGHTING INSTRUCTIONS

1.Stop! Read the safety information above on this label.

2.Set the thermostat to lowest setting.

3.When equipped with Effikal vent damper Model RVGP, place service switch in Hold Damper Open position.

4.Turn off all electrical power to the appliance.

5.When equipped with Johnson Controls vent damper Model M35, manually rotate damper blade in direction of arrow to Open position indicated on damper assembly.

6.Depress and move selector arm left •Gas valve — Robertshaw 7200 to OFF.

7.When equipped with vent damper, verify damper blade is in full open position.

Position

Selector

indicator

arm

(shown in

 

OFF position)

 

59332

8.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow "B" in the safety information above. If you don't smell gas, go to the next step.

9. Remove access panel located above burners.

10. Find pilot — follow metal tube from gas control. The pilot is between two burners behind the access panel.

11. Move selector arm on gas control right CGa-25 to CGa-6, EG-30 to EG-50, PEG-30 to PEG-50

to SET position.

59337

 

12.Hold selector arm in SET position and immediately light the pilot with a match. Continue to hold selector arm to SET for about one-half (1/2) minute after the pilot is lit.

13.Release selector arm. If pilot does not remain lit, repeat steps 6 through 13.

If the pilot will not stay lit after several tries, move

selector arm left Manual background to OFF and call your service technician or gas supplier.

14.Replace access panel.

15.Turn selector arm left Manual background to ON.

16.Turn on all electric power to the appliance.

17.When equipped with Effikal vent damper, place service switch in Automatic Operation position.

18.Set thermostat to desired setting.

19.Replace front panel.

TOTURN OFF GASTOTHE APPLIANCE

1.

Set the thermostat to lowest setting.

3.

Remove front panel.

 

2.

Turn off all electric power to the appliance if service is to

4.

Depress and move selector arm left

to OFF.

 

be performed.

5.

Replace front panel.

 

 

 

 