Weil-McLain manual Start-up, WGO/WTGO see Figure, If burner does not fire, check for

Models: WGO

1 12
Download 12 pages 12.23 Kb
Page 5
Image 5
Start-up

Start-up

WGO/WTGO (see Figure 1):

1.If burner does not fire, check for:

Service switch on boiler or additional switches turned off.

Fuses or breaker switch tripped. Thermostat set below room temperature. Fuel valves turned off.

Not enough oil in tank to supply burner.

Temperature -

Pressure Gauge

Water

Relief Valve

Service

Switch on

Boiler

Burner

Disconnect

Plug

2.Correct problems found in step #1. If burner does not fire, press reset button on burner primary control only once. Repeated presses will deposit oil in combustion chamber.

DANGER Burner must never be fired when oil is in combustion chamber. Immedi- ately call qualified service technician.

3.If burner still does not fire, call qualified service technician.

Circulator

Limit Control

(on WGO)

Combination

Limit Control and

Tankless Heater

Control

(on WTGO)

Located in tankless

heater plate

Reset Button on

Burner Primary

Control

Burner Primary

Control

WGO and WTGO Boilers

Figure 1

5

Page 5
Image 5