Well Traveled Living 60255 manual Step, Always UNPLUG unit when not in use

Models: 60255

1 10
Download 10 pages 2.49 Kb
Page 6
Image 6
Always UNPLUG unit when not in use!

This appliance MUST be grounded.

*When using outdoors, we recommend using a certified GF I(Ground Fault Interrupt)outlet to protect against electrical shock.

*Ensure that the heater mounting bracket is SECURELY fastened to the wall,patio overhang or house eave.

*Route electrical cable AWAY from main body of heater which gets very hot.

*Do NOT cover or obstruct the main body of the heater during use.

*All installations must be in accordance with I.E.E. safety regulations or equivalent. If you are unsure, consult an electrical service professional.

*Avoid the use of extension cord with this appliance.If one is used,

it MUST be at least a 14/3 wire, grounded cord, 50ft max. length.

*Do not place any objects such as furniture, papers, clothing or curtains closer than 3 ft to the front and the side of the heater.

NOTE: your IR Heater main body, electrical components & bracket are fully factory assembled. Do NOT attempt to service or disassemble without proper instructions.

For optimal performance and safety concerns,we HIGHLY RECOMMEND that the Infrared Heater

Head be operated at a min. of84''ht. with a 45-55 degree angleof operational spread.

To Adjust The IR Head Unit:

Swivel head unit up or down to desired position. The head unit must be at a 45-55 degree angle for optimal operation and output.There should only be a moderate amount of tension to maintain the swivel bracket. If it becomes too loose, tighten hex nuts and bolts at swivel points on head unit bracket.

The adjust angle of Head Unit is less than 45 degree.

Note:Be sure electrical cord is grouded and positioned away from head unit.

Min head unit clearance from combustibles 10" wall and 12" ceiling

Creates a generous zone of comfort!

1500W

Step 1

Before plug your Infrared Heating System, adjust the head unit angle as desired. Do NOT touch the head unit during operation or for 30 minutes AFTER unplug.

The head units GETS VERY HOT!

Refer to coverage area in Fig. 7 for best positioning location and heat spread/coverage.

84"

Uses standard 120V household

current 10.8ft

Quartz Halogen

Lamp

45degrees angle of heat spread

10ft

19ft

Step 2

The infrared electric heating system comes equipped with a heavy duty , 16/3 gauge wire and grounded plug. This appliance must be used with an outlet that has been installed and grounded in accordance with all local codes and ordinances. Makes sure that the heater is connected to an outlet having the same configuration as the plug shown in Fig. 8. Do NOT use an adapter with this product. Check with a licensed electrician if the grounding instructions are not understood completely or if the wall outlet does not match the plug.

Grounding instructions

The instruction manual of grounded heaters shall include the following or equivalent wording: (In the case of a heater rated for a nominal 120 voilts.) This heater is for use on 120 voits.The cord has a plug as shown at Ain Figure 65.1 An adapter as shown at C is available for connecting three-blade grounding-typeplugs to two-slot receptacles.The gree grounding lug extending from the adapter must be connected to a permanent ground such as a properly grounded outlet box.The adapter should not be used if a three-slot grounded receptacle is available.

SAFE for INDOOR Applications too!

Step 3

Always UNPLUG unit when not in use!

Your infrared electric heating system is ready to enjoy.Plug the appliance in and begin

enjoying the warmth!

Page 6
Image 6
Well Traveled Living 60255 manual Step, Always UNPLUG unit when not in use, This appliance MUST be grounded