Image 11
TROUBLESHOOTING SUGGESTIONS

TROUBLESHOOTING SUGGESTIONS

DESCRIPTION

POSSIBLE PROBLEM

 

SUGGESTED REMEDY

Fryer will not heat

Not plugged in or circuit breaker

 

Plug into proper receptacle

 

tripped

 

Reset circuit breaker

 

Temperature control knob not set to

 

Set to desired temperature

 

desired temperature

 

 

 

 

Hi-limit safety tripped

 

Clean element1, reset hi-limit

 

Damaged internal component

 

Contact Wells Authorized Service

 

 

 

 

Agency for repairs

Fryer will not maintain

Temperature control thermostat

 

Clean element2

temperature

thermobulb contaminated with

 

 

 

 

cooking debris

 

 

 

 

Damaged internal component

 

Contact Wells Authorized Service

 

 

 

 

Agency for repairs

Fryer leaks oil

Damaged frypot

 

Contact Wells Authorized Service

 

 

 

 

Agency for repairs

Element head will not

Frypot out of position, or has excess

 

Check frypot for position

raise, will not stay in the

cooking debris in bottom

 

Clean frypot

up position, or will not

Damaged hinge bracket or support

 

 

Contact Wells Authorized Service

 

lower

 

 

 

rod

 

 

Agency for repairs

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1The hi-limit safety is designed to shut down the fryer if the oil temperature exceeds 440ºF. A build-up of cooking debris between the heating element and the thermobulb of the hi-limit safety will cause the hi-limit to trip prematurely. Clean the element so that oil may circulate freely between the element and the thermobulb. Reset the safety by pressing the red button on the bask of the element head.

2A build-up of cooking debris between the heating element and the thermobulb temperature control thermostat will cause inconsistent temperatures. Clean the element so that oil may circulate freely between the element and the thermobulb.

9