Wells F-88 INSTALLATION continued, Electrical Shock Hazard, Fryer Electrical Installation

Models: F-88

1 14
Download 14 pages 54.29 Kb
Page 7
Image 7
INSTALLATION (continued)

INSTALLATION (continued)

WARNING: ELECTRIC SHOCK HAZARD

All servicing requiring access to non-insulated electrical components must be performed by a factory authorized technician.

DO NOT open any access panel which requires the use of tools. Failure to follow this warning can result in severe electrical shock.

M302 p/n 307589 OpM Countertop Autolift Fryers

FRYER ELECTRICAL INSTALLATION

Countertop autolift fryers must be connected directly to a suitable electric circuit. Conduit and strain relief must be provided by the electrician. Refer to nameplate for voltage and amperage requirements. Single phase fryers require a 208VAC or 240VAC 1ø circuit with gound. Three phase fryers require a 208VAC or 240VAC 3ø ciruit with ground.

Raise the element head, remove the frypot and the cover at the rear of the fryer to gain access to the terminal block. The electrical inlet is provided by a knock-out in the rear panel.

If an equipment shutdown interface is required by local fire code, the flame sensor terminal block may be accessed by removing the back panel. Replace the jumper of the terminal block with wiring to a normally closed contact of the building fire management system.

DO NOT connect power to the flame sensor terminal block. Wiring and contacts must be capable of handling 30 amps.

F-68 and F-88 FRYERS ARE SHIPPED FROM THE FACTORY WIRED FOR 3ø. Conversion to single phase is the responsibility of the electrician.

CAUTION:

RISK OF

FRYER ELECTRICAL INSTALLATIONELECTRICAL SHOCK HAZARDDAMAGE

DO NOT connect or energize this appliance until all installation instructions are read and followed. Damage to the appliance will result if these instructions are not followed.

CAUTION:

ELECTRICAL Manual backgroundManual backgroundSHOCK HAZARD

The ground lug of the fryer must be connected to a suitable building electric ground.

IMPORTANT: Damage due to being connected to the wrong voltage or phase is NOT covered by warranty.

NOTE:

Fryers are shipped from the factory with the basket lift in the UP position.