TROUBLESHOOTING SUGGESTIONS

TROUBLESHOOTING SUGGESTIONS

DESCRIPTION

POSSIBLE PROBLEM

SUGGESTED REMEDY

 

Fryer will not heat

Not plugged in or circuit breaker

Plug into proper receptacle

 

 

 

tripped

Reset circuit breaker

 

 

 

Fuse blown

Contact Wells Authorized Service

 

 

 

 

Agency for repairs

 

 

 

Temperature control knob not set to

Set to desired temperature

 

 

 

desired temperature

 

 

 

 

Hi-limit safety tripped

Clean element1, reset hi-limit

 

 

 

Damaged internal component

Contact Wells Authorized Service

 

 

 

 

Agency for repairs

 

Fryer will not maintain

Temperature control thermostat

Clean element2

 

temperature

thermobulb contaminated with

 

 

 

 

cooking debris

 

 

 

 

Damaged internal component

Contact Wells Authorized Service

 

 

 

 

Agency for repairs

 

Fryer leaks oil

Damaged frypot

Contact Wells Authorized Service

 

 

 

 

Agency for repairs

 

 

 

 

 

 

Element head will not

Frypot out of position, or has excess

Check frypot for position

 

raise

cooking debris in bottom

Clean frypot

 

Element head will not

 

 

 

stay in the up position

 

 

 

 

Element head will not

Damaged hinge bracket or support

Contact Wells Authorized Service

 

lower

rod

Agency for repairs

 

Basket lift will not lower

Timer not set

Set to desired cook time

 

 

 

Timer "PUSH" button not pushed

Push to start

 

 

 

 

 

 

 

 

Damaged internal component

Contact Wells Authorized Service

 

 

 

 

Agency for repairs

 

Basket lift will not raise

Damaged internal component

Contact Wells Authorized Service

 

Agency for repairs

 

 

 

 

 

1The hi-limit safety is designed to shut down the fryer if the oil temperature exceeds 440ºF. A build-up of cooking debris between the heating element and the thermobulb of the hi-limit safety will cause the hi-limit to trip prematurely. Clean the element so that oil may circulate freely between the element and the thermobulb. Reset the safety by pressing the red button on the back of the element head.