Wells F-886 Agency Listing Information, Installation, Unpacking & Inspection, IMPORTANT This is a

Models: F-886

1 16
Download 16 pages 61.67 Kb
Page 6
Image 6
AGENCY LISTING INFORMATION

AGENCY LISTING INFORMATION

This appliance conforms to NSF Standard 4 for sanitation only if installed in accordance with the supplied Installation Instructions.

This appliance is Underwriters Laboratory recognized (INSTALLATION). Since this appliance is only a single component of a complete installation, the finished installation of this UNPACKING & INSPECTION unit requires additional evaluations to Underwriters Laboratory standards.

Refer to Installation Instructions included with the appliance for Underwriters Laboratories conditions of acceptability, electrical requirements and other installation concerns.

STD 4

INSTALLATION

UNPACKING & INSPECTION

Carefully remove the appliance from the carton. Remove all protective plastic film, packing materials and accessories from the appliance before connecting electrical power or otherwise performing any installation procedure.

Carefully read all instructions in this manual and the Installation Instruction Sheet packed with the appliance before starting any installation.

Read and understand all attached labels and diagrams.

Carefully account for all components and accessories before discarding packing materials. Store all accessories in a convenient place for later use.

CUT-OUT AND INSTALLATION

Cutouts

a.Fryers may be installed in METAL COUNTERS ONLY.

b.Cutout dimensions for fryers and control panels are listed on the Installation Instructions provided with the fryer.

c.Refer to the Installation Instructions for Underwriters Laboratories Conditions of Acceptability.

Mounting the fryer:

a.Verify that provided sealants are applied to the under side of the fryer top flange prior to setting the unit into the cutout.

b.After installation, verify that the tabs on the Wellsloks are turned out to lock the appliance into the counter (see Fig. 2).

c.Apply a thin bead of food-grade silicone sealant around the flange to seal it to the counter.

Refer to the Installation Instructions for required clearances. Maintain required clearances between the appliance and adjacent combustible and non-combustible surfaces.

Sufficient overhead clearance must be provided to allow the element assembly to be raised. Refer to the Installation Instruction Sheet for required clearances.

Avoid storing flammable or combustible materials near the appliance. This includes gasoline and other fuels, mops, rags and wrapping paper.

NOTE: DO NOT discard the carton or other packing materials until you have inspected the appliance for hidden damage and tested it for proper operation.

Refer to SHIPPING DAMAGE CLAIM PROCEDURE on the inside front cover of this manual.

IMPORTANT: This is a

GENERAL GUIDE.

For specific equipment and cutout dimensions, and other installation details, refer to the Installation Instructions supplied with the appliance.

Fig. 2 Set the Wellslloks

IMPORTANT: Water damage caused by failure to set Wellsloks, failure to install gasket, or failure to seal flange to counter is NOT covered by warranty.

4

Page 6
Image 6
Wells F-886 Agency Listing Information, Unpacking & Inspection, Cut-Out And Installation, IMPORTANT This is a