Wells HDHP-3630G English, Set Gas Pressure, Set Pilot Flame, Adjust Burner Flame, Adjustments

Models: HDHP-3630G HDHP-1230G HDHP2430G

1 30
Download 30 pages 60.59 Kb
Page 9
Image 9
SET GAS PRESSURE:

226 306627 OpManual for HDHP-Series Hot Plates

SET GAS PRESSURE:

Gas pressure regulator is factory set.

SET PILOT FLAME:

The pilot adjustments are located between the control valves for each set of burners. The right valve controls the front pilot; the left valve controls the rear pilot.

Using a small, flat-blade screwdriver, turn the screw clockwise to decrease the flame size, or counter-clockwise to increase the flame size.

Adjust the pilot flame to 1/4” high. Test for operation: inside and outside sections of the burner must light without undue delay. Drafty conditions may require a higher flame to allow the pilot to remain lit.

ADJUST BURNER FLAME:

Remove all burner control knobs, then remove the front panel.

Turn an individual burner on. The right knob controls the front burner; the left knob controls the rear burner.

Loosen the locking screw on the shutter.

Turn the shutter to admit more or less air as required. Adjust the air shutter until the flame is mostly blue in color.

Tighten the locking screw when finished. Replace the front panel and all knobs before returning the unit to service.

Fig. 3 Adjustments

IMPORTANT:

Adjustments must be performed by a qualified technician only.

IMPORTANT:

This hotplate is shipped from the factory equipped for either: natural gas and adjusted for sea level to 2000 feet elevation; or, propane (LP) gas and adjusted for sea level to 5000 feet elevation.

For operation other than listed above, contact your Authorized Wells Service Agency.

ENGLISH

7

Page 9
Image 9
Wells HDHP-3630G, HDHP-1230G, HDHP2430G English, Set Gas Pressure, Set Pilot Flame, Adjust Burner Flame, Adjustments