TROUBLESHOOTING SUGGESTIONS

M506 p/n 304964 OpManual WVOC-4 Series Ventless Hotplate Cooktop Convection Oven

TROUBLESHOOTING SUGGESTIONS

A.

NO PART OF THE APPLIANCE WILL HEAT

CAUTION:

1.

Verify that appropriate cooking controls are ON.

ELECTRIC

2.

Check electrical supply. Make sure service breaker is ON.

SHOCK HAZARD

3.

Make sure all filters are properly installed, and that no filter warning

 

 

lights are lit.

Removal of any cabinet panel

4.

Possible improper service wiring: Have a licensed electrician verify

will result in exposed

 

that all three legs of the 3ø service are properly connected

electrical circuits. Any

 

(i.e. Leg 1 to L1, Leg 2 to L2, Leg 3 to L3), and that all three legs are

procedure requiring the

 

of the proper voltage and phase.

removal of any cabinet panel

5.

Ansul® Fire Suppression System not charged.

must be performed by a

qualified technician only.

B. HOTPLATE WILL NOT HEAT

1.Verify that associated temperature control is set to the desired temperature.

2.Possible internal component damage: Have unit serviced by an Authorized Wells Service Agency.

C.CONVECTION OVEN WILL NOT HEAT See Error Codes diagram at right

1.Verify that the oven switch is ON and that the temperature control is set to the desired temperature.

2.Verify that the door is closed.

3.Hi-Limit control may have tripped: Allow unit to cool; Hi-Limit will reset automatically.

4.Blown fuse(s) (item 40): Correct cause of over-current and replace fuses with fuses having the same configuration and ratings.

5.Possible internal component damage: Have unit serviced by an Authorized Wells Service Agency.

D. CONVECTION OVEN FAN WILL NOT RUN

1.Verify that the oven switch is set to ON or FAN.

2.Verify that the fan switch is set to either HIGH or LOW.

3.Hi-Limit control may have tripped: Allow unit to cool; Hi-Limit will reset automatically.

4.Blown fuse(s): Correct cause of over-current and replace fuses with fuses having the same configuration and ratings.

5.Possible internal component damage: Have unit serviced by an Authorized Wells Service Agency.

NOTE: Other than the ventilator filters, there are no user serviceable components in the appliance. In all cases of damage or component malfunction, contact your Authorized Wells Service Agency for repairs.