![HINGE ADJUSTMENT](/images/new-backgrounds/57389/5738949x1.webp)
HINGE ADJUSTMENT | CAUTION: | |||
PRECAUTIONS: | None | BURN HAZARD | ||
Allow appliance to cool | ||||
FREQUENCY: |
|
| ||
Monthly, at a Minimum; or, As Needed | completely before adjusting. | |||
TOOLS: | Phillips (+) Screwdriver |
| ||
| 7/16" Nut Driver |
| ||
| 7/8" and |
| ||
|
|
|
| |
|
|
|
|
THE FOLLOWING PROCEDURE IS TO BE
PERFORMED BY QUALIFIED PERSONNEL ONLY
1. Remove bottom panel to access pivot.ALIGNMENT CHECK
BOTTOM
PANEL
M506 p/n 304964 OpManual
2.Gap between top of door and frame , and between bottom of door and frame must be approximately equal
Adjust height of door by loosening jamb nut, then turning pivot on its screw mounting. Clockwise lowers the door height.
3.Gap between left side of door and frame must be the same from top to bottom
Adjust door for plumb by loosening holding screws. Turn adjusting bolt to increase or decrease gap at bottom. Clockwise increases gap.
4.Gap between top of door and frame must be the same from side to side
Adjust door for level by loosening holding screws, then raising or lowering
5.Reinstall bottom panel.
Procedure is complete
23
CLEARANCES
EQUAL