6. DIAG. TEST OPERATION
6.3 PARAMETER SETTING MODE
6.3.14 Threshold Manual Fine Adjustment for the Feed Gap Sensor
Power off
Turn on the power while holding down the [FEED] key and [PAUSE] key.
< 1 > D I A G N O S T I C | V 1 . O A |
Press the [PAUSE] key.
< 2 > P A R A M E T E R S E T
Press the [PAUSE] key sixteen times.
T H R E S H O L D T | 1 . 4 V |
Press the [FEED] key or [RESTART] key to fine adjust the feed gap sensor manual threshold.
■[FEED] key:
Pressing the [FEED] key onetime is a
■[RESTART] key:
Pressing the [RESTART] key onetime is a +0.1V change, up to 4.0V.
Press the [FEED] key and [RESTART] key at the
same time.
Press the [PAUSE] key.
Continued on Section
6.3.15Kanji Code Selection.
NOTES: 1. Holding the [FEED] key or [RESTART] key down for more than 0.5 seconds enables a fast forward.
2.A changed threshold fine adjustment value is stored in memory by pressing the [PAUSE] key.
3.The above operations do not require any more threshold setting.