2. MAJOR UNIT REPLACEMENT

EM18-33010A

2.3 REPLACING THE RIBBON MORTORS

2.3 REPLACING THE RIBBON MOTORS

CAUTION:

NEVER separate the ribbon motors from the attaching plate because doing so will change their adjustment.

1)Disconnect the connector and remove the two SM-3x5B screws to detach the ribbon motors.

FLOIL G-488

Attaching Plate

FLOIL

FLOIL G-488

Ribbon Motor

Screw (SM-3x5B)

Connector (Red)

Connector (Black)

Dowels

Attaching Plate

Ribbon Motor

Fig. 2-8

Screw (SM-3x5B)

 

2)Replace the ribbon motors, then align the dowels to attach the ribbon motors. Reassemble in the reverse order of removal.

2.4 REPLACING THE TAKE-UP MOTOR

CAUTION:

NEVER separate the take-up motor from the bracket because doing so will change the adjustment.

NOTE: The following procedure can be employed without removing the top cover and left side cover.

1)Remove the four FL-3x5 screws to detach the motor cover.

2)Remove the connector for the rewind full sensor (LED).

3)Disconnect the connector from the CN1 on the PWM PC board and remove the two FL-3x5 screws to detach the take-up motor.

PWM PC Board

Bracket

Connector (CN1)

Screw (FL-3x5)

Motor Cover

Screw (FL-3x5)

Take-up Motor

Connector

Fig. 2-9

4)Replace the take-up motor, then align the dowels to attach the motor cover and rewind full sensor (Tr).

2-5

Page 8
Image 8
Toshiba B-570 manual Replacing the Ribbon Motors, Replacing the TAKE-UP Motor