6-24
EM18-33010A
6. DIAG. TEST OPERATION

NOTES: 1 Holding the [FEED] key or [RESTART] key down for more than 0.5 seconds enables

a fast forward.

2. A changed print tone value is stored in memory by pressing the [PAUSE] key.

3. Fine adjustment value equals to the sum of the values set by the PC command and

system mode (key operation) and each max. value is

±

10 step. However, the upper

limit of the adjustment value is decided according to the print speed to protect the print

head. If the set value exceeds the following upper limit, it is automatically corrected

to the proper value.

Upper Limit: 3”/sec.: +10 step, 5’’/sec.: +5 step, 8”/sec,: +2 step

[FEED] key: Pressing the [FEED] key one
time is a -1 step change, up to
-10 steps. (See NOTE 2.)
[RESTART] key:Pressing the [RESTART] key
one time is a +1 step change,
up to +10 steps. (See NOTE 2.)
[FEED] key: Pressing the [FEED] key one
time is a -1 step change, up to
-10 steps. (See NOTE 2.)
[RESTART] key:Pressing the [RESTART] key
one time is a +1 step change,
up to +10 steps. (See NOTE 2.)
(Thermal transfer printing fine adjustment)
(Thermal direct printing fine adjustment)
(Revision Date: Jan. 14 ‘99)
6.3 PARAMETER SETTING MODE
6.3.5 Print Tone Fine Adjustment
<1 DIAGNOSTIC V1.0A
>
<2 PARAMETER SET
>
Power off
TO E ADJUST <T> +0
N
O E ADJUST D +0
NT <>
Turn on the power while
holding down the [FEED]
key and [PAUSE] key.
Press the [FEED] key.
Press the [PAUSE] key five times.
Press the [FEED] or
[RESTART] key to adjust
the feed length.
(See NOTE 1.)
Press the [PAUSE] key.
(See NOTE 3.)
Press the [FEED] or
[RESTART] key to fine
adjust the print tone.
(See NOTE 1.)
Press the [FEED] key
and [RESTART] key
at the same time.
Press the [PAUSE] key.
Continued on Section 6.3.6
Character code selection.