6. DIAG. TEST OPERATION

EM18-33010A (Revision Date: Dec. 10 ‘99)

6.3 PARAMETER SETTING MODE

6.3 PARAMETER SETTING MODE

The following items are set in the parameter setting mode. The values set in this mode are printed on the sample print of the maintenance counter. Setting procedure and functions are provided below.

Power off

Turn on the power while holding down the [FEED] key and [PAUSE] key.

< 1 > D I A G N O S T I C

V 1 . 0 A

 

 

 

 

 

 

Press the [FEED] key.

 

< 2 > P A R A M E T E R S E T

Press the [PAUSE] key.

F E E D A D J U S T

+ 0 . 0 m m

Press the [PAUSE] key.

C U T A D J U S T

+ 0 . 0 m m

Press the [PAUSE] key.

B A C K F E E D A D J . + 0 . 0 m m

Press the [PAUSE] key.

X A D J U S T

+ 0 . 0 m m

Press the [PAUSE] key.

 

T O N E A D J U S T < T >

+ 0

Press the [PAUSE] key.

 

T O N E A D J U S T < D >

+ 0

Press the [PAUSE] key.

 

F O N T C O D E

P C - 8 5 0

Press the [PAUSE] key.

Z E R O F O N T

 

0

Press the [PAUSE] key.

 

C O D E

 

A U T O

Press the [PAUSE] key.

 

R I B B O N

T R A N S .

Press the [PAUSE] key.

 

R I B B O N A D J < F W S >

+ 0

Press the [PAUSE] key.

 

R I B B O N A D J < B A K >

+ 0

Press the [PAUSE] key.

 

S T A T U S T Y P E

 

1

Press the [PAUSE] key.

 

S T A C K E R S Y S T E M

 

O F F

Press the [PAUSE] key.

 

T H R E S H O L D R

 

1 . 0 V

Press the [PAUSE] key.

 

T H R E S H O L D T

 

1 . 4 V

Press the [PAUSE] key.

 

K A N J I C O D E

T Y P E 1

Press the [PAUSE] key.

 

E U R O C O D E

B O H

Press the [PAUSE] key.

 

D T R / R T S

D T R

Press the [PAUSE] key.

 

I N P U T P R I M E

O N

Press the [PAUSE] key.

 

6-13