6. DIAG. TEST OPERATION
6.5 SENSOR SETTING MODE
6.5 SENSOR SETTING MODE
Thermistor check and black mark/feed gap sensor settings are provided in the sensor setting mode. The value set in this mode is printed as data of sensor 2 in Automatic diagnosis printing in self test mode.
6.5.1Thermistor Check
Thermistor check should be performed to check the environmental temperature and print head temperature after the excess head temp. error occurs or batch printing is performed for a long time.
Power off
Turn on the power while holding down the [FEED] key and [PAUSE] key.
< 1 > D I A G N O S T I C | V 1 . O A |
Press the [FEED] key three times.
<4 > S E N S O R A D J U S T M E N T
Press the [PAUSE] key.
[ H E A D ] 2 . 5 V [ A I R ] 2 . 0 V
Press the [FEED] key and [RESTART] key at the same time.
[HEAD] 2.5 V | [AIR] 2.0 V |
Thermistor status (0.0 ~ 5.0 V)
Environmental temperature
Thermistor status (0.0 ~ 5.0 V)
Print head
NOTE: Since the thermistor is supervised every 200 ms while displaying the status, the display could vary.