6.DIAG. TEST OPERATION

6.6.1Maintenance Counter Clear

EM18-33010A

6.6. RAM CLEAR MODE

Power off

Turn on the power while holding down the [FEED] key and [PAUSE] key.

< 1 > D I A G N O S T I C

V 1 . O A

Press the [FEED] key four times.

< 5 > R A M C L E A R

Press the [PAUSE] key. Press the [PAUSE] key.

N O R A M C L E A R

Press the [FEED] key and [RESTART] key at the same time.

Press the [FEED] key.

(or press the [RESTART] key twice.)

M A I N T E C O U N T E R C L E A R

Press the [PAUSE] key.

C O M P L E T E

Turn off the power (See NOTE.)

NOTE: Confirm that “COMPLETE” is displayed, then turn the power off.

6-55