6. DIAG. TEST OPERATION

EM18-33010A (Revision Date: Dec. 10 ‘99)

6.3 PARAMETER SETTING MODE

Parameter Setting Mode Table

Mode Name

 

Function

 

 

 

 

FEED ADJUST

Using this parameter the feed length is fine adjusted.

 

 

 

 

CUT ADJUST

Using this parameter the cut position or strip position is fine adjusted.

 

 

 

 

BACK FEED ADJ.

Using this parameter the back feed length from the cut/strip position to the

 

home position is fine adjusted.

 

 

 

 

X ADJUST

This setting is used to finely adjust print position in the X axis.

 

 

 

 

TONE ADJUST <T>

Using this parameter the print tone is fine adjusted. The longer the print

(Thermal transfer printing)

pulse width, the darker the print tone becomes. The shorter, the lighter

TONE ADJUST <D>

the print tone becomes.

 

 

 

 

 

(Thermal direct printing)

 

 

 

 

 

 

 

 

 

FONT CODE

The character code either PC-850 or PC-8 is selected.

ZERO FONT

The font zero either 0 or ø is selected.

 

 

 

 

 

 

CODE

The command code out of AUTO, ESC/LF/NUL, or {

 

} is selected.

 

 

 

 

 

 

 

RIBBON

Ribbon type either transmissive or non-transmissive is selected.

 

 

 

 

RIBBON ADJ <FWD>

Using this parameter the torque of the ribbon motors is fine adjusted.

(Ribbon feed motor)

 

 

 

 

 

RIBBON ADJ <BAK>

 

 

 

 

 

(Ribbon feed motor)

 

 

 

 

 

 

 

 

 

STATUS TYPE

Whether or not the strip wait status (05H) is sent in response to the status

 

request command from the PC is selectable.

 

 

 

 

STACKER SYSTEM

Use of the Stacker is selected.

 

(not supported by QQ/QP models.)

 

 

 

 

THRESHOLD R

The threshold of the black mark sensor is manually fine adjusted.

 

 

 

 

THRESHOLD T

The threshold of the feed gap sensor is manually fine adjusted.

 

 

 

 

KANJI CODE

Kanji code either Windows code or original code is selected.

 

(not supported by QQ/QP models.)

 

 

 

 

EURO CODE

EURO code is selected from 20H to FFH.

 

 

 

 

DTR/RTS

Transmission Control mode is selected from DTR and RTS.

 

 

 

 

INPUT PRIME

Reset ON/OFF when the

 

signal on is selcted.

INPUT • PRIME

 

 

 

 

 

 

6-14

Page 45
Image 45
Toshiba B-570 manual Parameter Setting Mode Table