6. DIAG. TEST OPERATION

EM18-33010A (Revision Date: Dec. 10 ‘99)

6.3 PARAMETER SETTING MODE

6.3.13 Threshold Manual Fine Adjustment for the Black Mark Sensor

Power off

Turn on the power while holding down the [FEED] key and [PAUSE] key.

< 1 > D I A G N O S T I C

V 1 . O A

Press the [PAUSE] key.

< 2 > P A R A M E T E R S E T

 

 

 

 

 

 

 

 

 

 

 

 

Press the [PAUSE] key fifteen times.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

T H R E S H O L D R

 

1 . 0 V

 

 

 

 

 

 

 

 

 

 

 

 

Press the [FEED] key or

[FEED] key:

[RESTART]

key to

fine

 

Pressing the [FEED] key onetime is a -0.1V

adjust the

black

mark

 

change, up to 0.0V

sensor manual threshold.

[RESTART] key:

 

 

 

 

Pressing the [RESTART] key onetime is a

 

 

 

 

+0.1V change, up to 4.0V.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Press

the [PAUSE] key.

Press the [FEED] key and [RESTART] key at the same time.

Continued on Section

6.3.14Threshold Manual Fine Adjustment for the Feed Gap Sensor.

NOTES: 1. Holding the [FEED] key or [RESTART] key down for more than 0.5 seconds enables a fast forward.

2.A changed threshold fine adjustment value is stored in memory by pressing the [PAUSE] key.

3.The above operations do not require any more threshold setting.