6. DIAG. TEST OPERATION
6.3 PARAMETER SETTING MODE
6.3.13 Threshold Manual Fine Adjustment for the Black Mark Sensor
Power off
Turn on the power while holding down the [FEED] key and [PAUSE] key.
< 1 > D I A G N O S T I C | V 1 . O A |
Press the [PAUSE] key.
< 2 > P A R A M E T E R S E T |
|
|
| ||
|
|
| |||
|
|
|
|
|
|
Press the [PAUSE] key fifteen times. |
|
| |||
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
| |
T H R E S H O L D R |
| 1 . 0 V |
|
| |
|
|
|
| ||
|
|
|
|
|
|
Press the [FEED] key or | ■ [FEED] key: | ||||
[RESTART] | key to | fine |
| Pressing the [FEED] key onetime is a | |
adjust the | black | mark |
| change, up to 0.0V | |
sensor manual threshold. | ■ | [RESTART] key: | |||
|
|
|
| Pressing the [RESTART] key onetime is a | |
|
|
|
| +0.1V change, up to 4.0V. | |
|
|
|
|
| |
|
|
|
|
|
|
|
|
| Press | the [PAUSE] key. |
Press the [FEED] key and [RESTART] key at the same time.
Continued on Section
6.3.14Threshold Manual Fine Adjustment for the Feed Gap Sensor.
NOTES: 1. Holding the [FEED] key or [RESTART] key down for more than 0.5 seconds enables a fast forward.
2.A changed threshold fine adjustment value is stored in memory by pressing the [PAUSE] key.
3.The above operations do not require any more threshold setting.