6. DIAG. TEST OPERATION

EM18-33010A

6.3 PARAMETER SETTING MODE

6.3.3Back Feed Length Fine Adjustment

Power off

Turn on the power while hoding down the [FEED] key and [PAUSE] key.

< 1 > D I A G N O S T I C

V 1 . 0 A

Press the [FEED] key.

< 2 > P A R A M E T E R S E T

Press the [PAUSE] key three times.

B A C K F E E D A D J . + 0 . 0 m m

Press the [FEED] or [RESTART] key to adjust the feed length.

(See NOTE 1.)

[FEED] key:

Pressing the [FEED] key one

 

time is a -0.5 mm change, up to

 

-9.5 mm. (See NOTE 2.)

[RESTART] key: Pressing the [RESTART] key one time is a +0.5 mm change, up to +9.5 mm. (See NOTE 2.)

Press the [FEED] key

Press the [PAUSE] key.

and [RESTART] key

 

 

at the same time.

 

 

 

 

 

 

 

 

 

 

 

 

Continued on Section 6.3.4

 

 

 

 

X axis fine adjustment.

NOTES: 1. Holding the [FEED] key or [RESTART] key down for more than 0.5 seconds enables a fast forward.

2.Max. fine adjustment ±9.9 mm = Key fine adjustment value (± 9.5 mm) + PC fine adjustment value (±9.9 mm)

When the value reaches the maximum, the value remains unchanged even if the subsequent fine adjustment is performed.

3.A changed back feed value is stored in memory by pressing the [PAUSE] key.