6. DIAG. TEST OPERATION
6.3 PARAMETER SETTING MODE
6.3.3Back Feed Length Fine Adjustment
Power off
Turn on the power while hoding down the [FEED] key and [PAUSE] key.
< 1 > D I A G N O S T I C | V 1 . 0 A |
Press the [FEED] key.
< 2 > P A R A M E T E R S E T
Press the [PAUSE] key three times.
B A C K F E E D A D J . + 0 . 0 m m
Press the [FEED] or [RESTART] key to adjust the feed length.
(See NOTE 1.)
■ [FEED] key: | Pressing the [FEED] key one |
| time is a |
|
■[RESTART] key: Pressing the [RESTART] key one time is a +0.5 mm change, up to +9.5 mm. (See NOTE 2.)
Press the [FEED] key | Press the [PAUSE] key. | ||
and [RESTART] key |
|
| |
at the same time. |
|
| |
|
|
|
|
|
|
|
|
|
| Continued on Section 6.3.4 | |
|
| ||
|
| X axis fine adjustment. |
NOTES: 1. Holding the [FEED] key or [RESTART] key down for more than 0.5 seconds enables a fast forward.
2.Max. fine adjustment ±9.9 mm = Key fine adjustment value (± 9.5 mm) + PC fine adjustment value (±9.9 mm)
When the value reaches the maximum, the value remains unchanged even if the subsequent fine adjustment is performed.
3.A changed back feed value is stored in memory by pressing the [PAUSE] key.