6. DIAG. TEST OPERATION
6.3 PARAMETER SETTING MODE
6.3.1Feed Length Fine Adjustment
Power off
Turn on the power while holding down the [FEED] key and [PAUSE] key.
< 1 > D I A G N O S T I C | V 1 . 0 A |
Press the [FEED] key.
< 2 > P A R A M E T E R S E T
Press the [PAUSE] key.
F E E D A D J U S T | + 0 . 0 m m |
Press the [FEED] or [RESTART] key to adjust the feed length.
(See NOTE 1.)
■ [FEED] key: | Pressing the [FEED] key one time |
| is a |
mm. (See NOTE 2.)
■[RESTART] key: Pressing the [RESTART] key one time is a +0.5 mm change, up to +50.0 mm.
(See NOTE 2.)
Press the [FEED] key and [RESTART] key at the same time.
Press the [PAUSE] key.
Continued on Section 6.3.2 Cut/strip position fine adjustment.
NOTES: 1. Holding the [FEED] key or [RESTART] key down for more than 0.5 seconds enables a fast forward.
2.Max. fine adjustment ±50.0 mm = Key fine adjustment value (± 50.0 mm) + PC fine adjust ment value (± 50.0 mm)
When the value reaches the maximum, the value remains unchanged even if the subsequent fine adjustment is performed.
3.A change feed value is stored in memory by pressing the [PAUSE] key.