6. DIAG. TEST OPERATION
6.3 PARAMETER SETTING MODE
6.3.18 Reset Selection when the INPUT • PRIME Signal is ON.
Reset ON/OFF when the INPUT • PRIME signal ON is selected.
Power off
Turn on the power while holding down the [FEED] key and [PAUSE] key.
<1 > D I A G N O S T I C . V 1 . O A
Press the [FEED] key.
< 2 > P A R A M E T E R S E T
Press the [PAUSE] key 20 times.
I N P U T P R I M EO N
Select the "Reset ON/OFF when the INPUT • PRIME
signal is ON" with the [FEED] key or [RESTART] key.
•ON: The printer will restore to the initial status.
•OFF: The printer will not restore to the initial status.
Press the [PAUSE] key.
NOTES: 1. Holding the [FEED] key or [RESTART] key down for more than 0.5 seconds enable.
2.A changed “Reset ON/OFF when the INPUT • PRIME signal is ON” is stored in memory by pressing the [PAUSE] key.