6. DIAG. TEST OPERATION

EM18-33010A (Revision Date: Dec. 10 ‘99)

6.3 PARAMETER SETTING MODE

6.3.18 Reset Selection when the INPUT • PRIME Signal is ON.

Reset ON/OFF when the INPUT • PRIME signal ON is selected.

Power off

Turn on the power while holding down the [FEED] key and [PAUSE] key.

<1 > D I A G N O S T I C . V 1 . O A

Press the [FEED] key.

< 2 > P A R A M E T E R S E T

Press the [PAUSE] key 20 times.

I N P U T P R I M EO N

Select the "Reset ON/OFF when the INPUT • PRIME

signal is ON" with the [FEED] key or [RESTART] key.

ON: The printer will restore to the initial status.

OFF: The printer will not restore to the initial status.

Press the [PAUSE] key.

NOTES: 1. Holding the [FEED] key or [RESTART] key down for more than 0.5 seconds enable.

2.A changed “Reset ON/OFF when the INPUT • PRIME signal is ON” is stored in memory by pressing the [PAUSE] key.

6-40

Page 71
Image 71
Toshiba B-570 manual Reset Selection when the Input Prime Signal is on, Press the Pause key 20 times, P U T P R I M Eo N