2. MAJOR UNIT REPLACEMENT
2. MAJOR UNIT REPLACEMENT
2. MAJOR UNIT REPLACEMENT
WARNING!
Disconnect power cord before replacing important parts.
CAUTION:
1.NEVER separate the ribbon motors from the attaching plate (bracket), because doing so will change their adjustment. (See Fig.
2.NEVER remove the two screws painted red on the side of the print block. (See Fig.
3.NEVER remove the four screws on the side of the print block. (See Fig.
4.NEVER remove the four screws painted red fixing the right plate and reinforcing plate.
(See Fig.
5.NEVER remove unmentioned screws because doing so will change their adjustment.
1)Turn the power off.
2)Open the top cover to remove the four
3)Remove the seven screws
4)Disconnect the FAN motor connector from the PS unit.
Left Side Cover | Top Cover |
| |
| Screw |
FAN Motor | Damper |
| Screw |
Screw
Fig.
NOTE: Instructions to remove the top cover and left side cover are omitted from each removal/ installation procedure provided below.
■Lubrication
CAUTION: 1) Lubrication: During parts replacement
2) Kinds of oil: FLOIL G-488: 1 Kg can. (Part No. 19454906001).
Any machine is generally in its best condition when delivered; therefore, it is necessary to try to keep this condition. Unexpected failure occurs due to lack of oil, debris or dust. To keep its best condition, periodically clean the machine and apply proper kinds of oil to each part in which lubrication is needed.
Although the frequency of lubrication varies according to how much the machine is used, at least it is necessary to lubricate before the machine becomes dry. It is also necessary to wipe off excessive oil as it collects dirt.
CAUTION: Do not spray the inside of the printer with lubricants. Unsuitable oil can damage the mechanism.