![](/images/new-backgrounds/1149706/14970669x1.webp)
6. DIAG. TEST OPERATION
6.2 SELF TEST MODE
■Sample Print [Print Condition]
∙ Preset count | : 1 |
∙ Print speed | : 127 mm/sec. |
∙ Sensor | : No sensor |
∙Printing method : Thermal transfer
∙ Supply length | : 50 mm |
∙ Issuing mode | : Batch printing |
| (without rewinder) |
1) Maintenance Counter
(1) |
|
|
| TL FEED | 1882.3km | [PC] |
| |
|
|
|
| |||||
(2) |
|
|
| FEED |
| 20.5km | FEED | |
|
|
|
| |||||
(3) |
|
|
|
| 15.0km | CUT | ||
|
|
|
| |||||
(4) |
|
|
| CUT |
| 148150 | BACK | +3.0mm |
|
|
|
| |||||
(5) |
|
|
| HEAD U/D | 170 | TONE(T) | +3step | |
|
|
| ||||||
(6) |
|
|
| RIBBON |
| 32h | TONE(D) | +5step |
|
|
|
| |||||
(7) |
|
|
| SOLENOID | 0h | [KEY] |
| |
|
|
|
| |||||
(8) |
|
|
| 232C ERR | 1 | FEED | +5.0mm | |
|
|
| ||||||
(9) |
|
|
| SYSERR | 0 | CUT | ||
|
|
| ||||||
(10) |
|
|
| PW FAIL |
| 0 | BACK | +0.5mm |
|
|
|
| |||||
(11) |
|
| FONT | TONE(T) | +0step | |||
|
| |||||||
(12) |
|
| CODE | [ESC LF NUL] | TONE(D) | +1step | ||
|
| |||||||
(13) |
|
|
| RIBN | [TRANS.] | X ADJ. | +35.0mm | |
|
|
|
(25)RIBN ADJ. [PC] + 0 +0 [KEY] + 0 +0
(26)STATUS [OFF]
(27)THRESHOLD R 1.0V
(28)THRESHOLD T 1.4V
(29)KANJI [TYPE1]
(30)EURO CODE B0H
(31)STACKER [OFF]
(32)DTR/RTS [DTR]
(33)INPUT PRIME [ON]
(14)
(15)
(16)
(17)
(18)
(19)
(20)
(21)
(22)
(23)
(24)
Fig.
# | Item | Count Condition | Range | |
(1) | Total media distance | Counted when the feed motor drives to feed, print and | 0.0 ~ 3200.0 km | |
issue the media. (Counted also during ribbon save | ||||
| covered |
| ||
(2) | Media distance | operation and back feed.) [See NOTE 2]. | 0.0 ~ 200.0 km | |
|
|
|
| |
| Print distance | Counted while printing. (Feeding and issuing media, |
| |
(3) |
| and ribbon saving operation are not counted.) | 0.0 ~ 200.0 km | |
|
| [See NOTE 2.] |
| |
(4) | Cut count | Counts every cut. [See NOTE 3.] | 0 ~ 1000000 times | |
| Head up and down | Counts every up and down of the print head using the |
| |
(5) | count | solenoid for ribbon save operation. | 0 ~ 2000000 times | |
|
| (Up + Down = 1 count) [See NOTE 3.] |
| |
|
|
|
| |
| Ribbon motor driving | Counts when the ribbon motor drives to feed, print |
| |
(6) | time | and issue the media. (The driving time is not counted | 0 ~ 2000 hours | |
|
| during ribbon saving operation, but is during back |
| |
|
| feed.) [See NOTE 4.] |
| |
|
|
|
| |
(7) | Solenoid driving time | Counted during ribbon saving operation. | 0 ~ 1000 hours | |
| [See NOTE 4.] | |||
|
|
|
| |
(8) | Counted when a parity, overrun or framing error | 0 ~ 255 times | ||
error count | occurs. [See NOTE 5.] | |||
|
|
|
| |
(9) | System error count | Counted when a | 0 ~ 15 times | |
|
| undefined command is retrieved. |
| |
(10) | Momentary power | Counted when a momentary power failure occurs. | 0 ~ 15 times | |
| failure count |
|
| |
NOTES: 1. Item from (2) through (10) are initialized to “0” after RAM clear. |
|
2.If the distance is 5.5 m or less, it is rounded down and no data is added to the memory at power off.
3.If the count is 31 counts or less, it is rounded down and no data is added to the memory at power off.
4.If the driving time is 27 sec. or less, it is rounded down and no data is added to the memory at power off.
5.When a sent command results in an error, the same number as the data capacity of the command is counted by byte.