6. DIAG. TEST OPERATION

EM18-33010A (Revision Date Jun. 28, ’96)

6.3 PARAMETER SETTING MODE

6.3.9Ribbon Type Selection

Power off

Turn on the power while holding down the [FEED] key and [PAUSE] key.

< 1 > D I A G N O S T I C

V 1 . O A

Press the [FEED] key.

< 2 > P A R A M E T E R S E T

 

 

 

 

 

 

 

 

 

Press the [PAUSE] key ten times.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

R I B B O N

T R A N S .

 

 

 

Transmissive ribbon

 

 

Select either ribbon type with

the [FEED] key or [RESTART]

Transmissive:

With ribbon

key. (See NOTE 1 and 2.)

Non-transmissive: Ribbon end

Non-Transmissive ribbon

Transmissive: Ribbon end

Non-transmissive: With ribbon

Press the [PAUSE] key.

Press the [RESTART] key. (See NOTE 3.)

Continued on Section 6.3.10 Ribbon Motor Drive Voltage Fine Adjustment

NOTES: 1. Holding the [FEED] key or [RESTART] key down for more than 0.5 seconds enables a fast forward.

2.Non-transmissive (NON TRANS.) ribbon cannot be used so the ribbon type must be set to transmissive (TRANS.) ribbon.

3.A changed ribbon type is stored in memory by pressing the [PAUSE] key.

6-29

Page 60
Image 60
Toshiba B-570 Ribbon Type Selection, Press the Pause key ten times, ∙ Transmissive ribbon, Select either ribbon type with