OWNERS MANUAL

ROUTINE MAINTENANCE SCHEDULE

ROUTINE MAINTENANCE SCHEDULE

1)Drain water from the air tank, any moisture separators or transformers.

2)Check for any unusual noise and/or vibration.

3)Manually check all safety valves to make sure they are operating properly.

4)Inspect air filter, replace if necessary.

5)Inspect air lines and fittings for leaks; correct as necessary.

Each year of operation or if a problem is suspected:

Check condition of air compressor pump intake and exhaust valves.

Check condition of check valve. Replace if damaged or worn out.

Filling with oil:

1)Remove the oil filler plug.

2)Slowly pour the proper oil into the pump crankcase.

3)Always keep oil level in the middle of the sight glass.

Changing the oil:

Note: Every 300 hours or 3 months, whichever comes first.

1)Remove the oil drain plug. Allow oil to drain completely.

2)Replace the oil drain plug (The use of a sealing compound or Teflon tape to avoid leakage is recommended.)

3)Refill with the recommended oil to the proper level.

COLD WEATHER CONDITIONS

 

Ambient Temperatures at

SAE

ISO

 

 

Point of operation

Viscosity

Viscosity

 

 

-16°C TO 0°C (3.2°F - 32°F)

SAE 10W

ISO 32

 

 

 

 

 

 

 

1°C TO 26°C (33.8°F - 78.8°F)

SAE 20W

ISO 68

 

 

 

 

 

 

 

ABOVE 27°C (80.6°F)

SAE 30W

ISO 100

 

 

 

 

 

 

 

 

 

 

 

MAKITA - MAC700 / MAC2400 / MAC5200

13

Page 13
Image 13