OWNERS MANUALTROUBLESHOOTING GUIDE
| PROBLEM | CAUSE | CORRECTION |
|
|
|
|
|
|
| Motor will not run. (con’t) | Check valve is stuck open. | Remove and clean, or replace. |
|
|
| Loose electrical connections. | Check wiring connection inside |
|
|
|
| pressure switch and terminal |
|
|
|
| box area. |
|
|
| Possible defective capacitor. | Return to an Authorized |
|
|
|
| Warranty Service Center for |
|
|
|
| inspection or replacement if |
|
|
|
| necessary. |
|
|
| Paint spray on internal motor | Have checked at an |
|
|
| parts. | Authorized Warranty Service |
|
|
|
| Center. Do not operate the |
|
|
|
| compressor in the paint spray |
|
|
|
| area. See flammable vapor |
|
|
|
| warning. |
|
|
| Possible defective motor. | Have checked at an |
|
|
|
| Authorized Warranty Service |
|
|
|
| Center. |
|
|
| Fuse Blown, circuit breaker | Check fuse box for blown fuse |
|
|
| tripped. | and replace. If necessary, |
|
|
|
| reset circuit breaker. Do not |
|
|
|
| use a fuse or circuit breaker |
|
|
|
| with higher rating than |
|
|
|
| specified for your particular |
|
|
|
| branch circuit. |
|
|
|
| Check for low voltage |
|
|
|
| conditions and/or proper |
|
|
|
| extension cord. |
|
|
|
| Disconnect the other electrical |
|
|
|
| appliances from circuit or |
|
|
|
| operate the compressor on its |
|
|
|
| own branch circuit. |
|
|
| Pressure unloader valve on | Bleed the line by pushing the |
|
|
| pressure switch has not | lever on the pressure switch to |
|
|
| unloaded head pressure. | the "off" position; if the valve |
|
|
|
| does not open, replace it. |
|
|
|
|
|
|
| Regulator knob has continuous | Dirty or damaged regulator | Replace regulator. |
|
| air leak. Regulator will not shut | internal parts. |
|
|
| off at air outlet. |
|
|
|
|
|
|
|
|
|
|
|
|
|
MAKITA - MAC700 / MAC2400 / MAC5200 | 17 |