OWNERS MANUAL | INSTALLATION AND |
DESCRIPTION OF OPERATION ... Continued
PRESSURE SWITCH UNLOADING VALVE: The pressure switch unloading valve located on the side of the pressure switch, is designed to automatically release compressed air from the compressor head and the outlet tube when the air compressor reaches
PRESSURE SWITCH: The pressure switch automatically starts the motor when the air tank pressure drops to the factory set
SAFETY VALVE: If the pressure switch does not shut off the air compressor at its
OUTLET PRESSURE GAUGE: The outlet pressure gauge indicates the air pressure available at the outlet side of the regulator. This pressure is controlled by the regulator and is always less or equal to the tank pressure. See “Operating Procedures”.
TANK PRESSURE GAUGE: The tank pressure gauge indicates the air pressure in the tank.
REGULATOR: The air pressure coming from the air tank is controlled by the regulator knob. Turn the knob clockwise to increase pressure and
INSTALLATION AND BREAK-IN PROCEDURES
LOCATION OF THE AIR COMPRESSOR:
Locate the air compressor in a clean, dry and
LUBRICATION AND OIL:
CAUTION: Do not attempt to operate this air compressor without first adding oil to the crankcase. Serious damage will result from even limited operation unless filled with oil and broken in correctly. Make sure to closely follow initial
WARNING: Compressors are shipped without oil. A small amount of oil may be present in the pump upon receipt of the air compressor. This is due to factory testing and does not mean the pump contains oil.
MAKITA - MAC700 / MAC2400 / MAC5200 | 9 |