CONSOLE DIAGRAM
USING THE CONSOLE
Refer to the console diagram above. The function of each console control is explained below:
Temperature Display: During normal use this display shows the actual water temperature. When the Set Temp indicator is lit, the display shows the set temperature.
Light: This button turns the light on and off. When the light is on, the indicator above the light button will be lit. The light will automatically turn off after two hours.
Pump: This button turns the pump on and off. When the pump is running, the LED indicator above the but- ton will light. To turn the pump on high, press the but- ton once. The
Set Temp: This indicator will light when the tempera- ture is adjusted by using the up and down buttons. To adjust the temperature, press either the up or down buttons to select a new temperature. The thermostat can be set to heat the water from 41¡F to 104¡F. While you are setting the temperature, the tempera- ture display will show the new temperature. The new temperature will remain in the display for five seconds after you release the buttons. Then the Set Temp light will turn off and the display will return to the actual water temperature. The water heats at 6.0 to 8.0¡F per hour with the cover on.
Heat On: This LED indicator is lit when the spa is run- ning the heating cycle.
Filter On: This LED indicator is lit when the spa is running the filter cycle.
Note: To keep the heat and filter cycles from run- ning, shut off the circuit breaker or GFCI.
Air Control: Determines the amount of air that is in the spa jet system during operation. If the control is turned to the left, the amount of air flowing through the jets will increase. If the control is turned to the right, the amount will decrease.
Error Messages: When certain problems occur, the Temperature Display will show an error code. The error codes are explained below:
HL High temperature protection mode. If the water temperature rises above 115¡F, the heater will shut off. If the temperature rises above 122¡F, the high temperature circuit will shut off the entire system. In either case, once the water has cooled to normal, you can press any button to reset the system.
FrE Freeze protection mode. If the water tempera- ture falls below 40¡F, the pump will begin cycling the water through the heater to raise the temperature. This cycle will run for one minute and may be repeated as needed.
FLC Flow related problems. You will need to call our customer service department.
FLO Flow related problems. You will need to call our customer service department.
PrH High temperature probe problem. You will need to call our customer service department.
Prr Temperature probe problem. You will need to call our customer service department.
12