MOUNTING AND WIRING INSTRUCTIONS

MOUNTING AND WIRING INSTRUCTIONS

CAUTION: For fixtures labeled for outdoor and wet location use, provide a water-tight seal between the fixture and the mounting surface by using silicone or similar caulking.

NOTE: Underwriters Laboratories (UL) does not require all fixtures to have ground wires. These fixtures meet all UL specifications.

1.Turn off power at circuit box to avoid possible electric shock.

2.Thread mounting screws (A) into mounting bar (B) approximately 5/8 inch (see fig. 1).

3.Secure mounting bar (B) to outlet box (C) with outlet box screws (D) (not included).

4.Thread wires up through center hole (E) in mounting bar (B.)

5.Identify color coding of fixture wires (see figure 2 on page 11).

6.To connect wires, take black fixture wire (group A from fig. 2) and place evenly against black outlet box wire. Do not twist wires.

7.Fit wire connector (F from fig. 1) over wires and twist until there is a firm connection. If wire connector (F) easily comes off, reattach and check again for a firm connection (see figure 1).

8.Repeat steps 6 and 7with the white (group B from fig. 2) fixture and outlet box wires.

9.Partially thread green grounding screw (G) into side hole (H) on mounting bar (B) (see fig. 1).

10.Wrap ground wire from fixture and ground wire (metal or green wire) from outlet box

(C) around green grounding screw (G) on mounting bar (B).

11.Tighten green grounding screw (G). Do not over tighten.

12.Tuckwires inside outlet box (C).

FIXTURE ASSEMBLY INSTRUCTIONS

1.Raise canopy (I) to ceiling allowing mounting screws (A) to protrude through key slots

(J)in canopy (I) (see fig. 1).

2.Rotate canopy (I) clockwise until mounting screws (A) lock into narrow portion of key slots (J).

3.Install lamp(s). Do not exceed recommended wattage.

4.Secure glass shade (K) into canopy (I) with thumb screws (L).

5.Turn power back on at circuit box.