Image 4
MOUNTING AND WIRING INSTRUCTIONS

MOUNTING AND WIRING INSTRUCTIONS

NOTE: Underwriters Laboratories (UL) does not require all fixtures to have ground wires. These fixtures meet all UL specifications.

1.Turn off power at circuit box to avoid possible electric shock.

2.Thread mounting screws (A) into mounting bar (B) approximately 1/4 inch (see fig. 1).

3.Secure mounting bar (B) to outlet box (C) with outlet box screws (D) (not included).

4.Determine the combination of stems needed to achieve your desired length (4 stems provided. 2 long and 2 shorter).

5.Thread stem 1 (E1) into nipple 1 (F1).

6.Thread stem 2 (E2) into nipple 2 (F2).

7.If applicable, thread stem 3 (E3) and/or stem 4 (E4) in between stems (E1 and E2).

8.Identify color coding of fixture wires (see fig. 2).

9.To connect wires, take black fixture wire (group A from fig. 2) and place evenly against black outlet box wire. Do not twist wires.

10.Fit wire connector (G from fig. 1) over wires and twist until there is a firm connection. If wire connector (G) easily comes off, reattach and check again for a firm connection.

11.Repeat steps 9 and 10 with the white (group B from fig. 2) fixture wires and outlet box wires.

12.Partially thread green grounding screw (H) into side hole (I) on mounting bar (B) (see fig. 1).

13.Wrap ground wire from fixture around green grounding screw (H) leaving enough excess wire to then connect ground wire and outlet box wire with wire connector (G), if applicable.

14.Tighten green grounding screw (H). Do not over tighten.

15.Tuckwires inside outlet box (C).

16.Raise canopy (J) to ceiling and thread cap nuts (K) onto mounting screws (A) and tighten securely.

FIXTURE ASSEMBLY INSTRUCTIONS

Warning: This fixture is for indoor use only.

1.Install the glass shades(s) (L) and cap(s) (M) over the socket(s) (N), and secure retaining ring(s) (O) with the tool (P) (included).

2.Install lamp(s). Do not exceed recommended wattage.

3.Turn power back on at circuit box.