Whirlpool 19760268A Installation Instructions, Electrical Requirements, Prepare Location

Models: 19760268A

1 28
Download 28 pages 623 b
Page 6
Image 6
Electrical Requirements

Electrical Requirements

Electrical Shock HazardWARNING

Electrical Shock Hazard

Disconnect power before servicing.

Replace all parts and panels before operating.

Failure to do so can result in death or electrical shock.

IMPORTANT: The hood must be electrically grounded in accordance with local codes and ordinances, or in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70, latest edition, or Canadian Electrical Code, CSA C22.1.

If codes permit and a separate ground wire is used, it is recommended that a qualified electrical installer determine that the ground path is adequate.

A copy of the above code standards can be obtained from:

National Fire Protection Association

One Batterymarch Park, Quincy, MA 02269

CSA International

8501 East Pleasant Valley Road

Cleveland, Ohio 44131-5575

A 120-volt, 60-Hz, AC-only, 15-amp, fused electrical circuit is required. A time-delay fuse or circuit breaker is also recommended. It is recommended that a separate circuit serving only this hood be provided.

Do not ground to a gas pipe.

Check with a qualified electrician if you are not sure range hood is properly grounded.

Do not have a fuse in the neutral or ground circuit.

The range hood must be connected with copper wire only.

The range hood should be connected directly to the fused disconnect (or circuit breaker) box through flexible armored cable or flexible metallic conduit.

Wire sizes must conform to the requirements of the National Electrical Code, ANSI/NFPA 70, latest edition, or CSA Standard C22.1-94, Canadian Electrical Code, Part 1 and C22.2 No. 0-M91, latest edition, and all local codes and ordinances.

INSTALLATION INSTRUCTIONS

Prepare Location

Do not cut a joist or stud unless absolutely necessary. If a joist or stud must be cut, then a supporting frame must be constructed.

Before making cutouts, make sure there is proper clearance within the ceiling or wall for exhaust vent.

Hood installation height above cooktop is the user's preference. The lower the hood above the cooktop, the more efficient the capturing of cooking odors, grease and smoke.

Check your ceiling height and the hood height maximum before you select your hood.

WARNING

Excessive Weight Hazard

Use two or more people to move and install range. Failure to do so can result in back or other injury.

2.Select a flat surface for assembling the unit. Cover that surface with a protective covering.

3.Determine and mark the centerline on the wall where the canopy hood will be installed.

4.Select a mounting height, minimum 30" (76.2 cm), above the cooking surface and mark reference line on the wall.

5.Tape template in place, aligning the template centerline and bottom of template with hood bottom line and with the centerline marked on the wall.

A

D

B

1.If possible, disconnect and move freestanding or slide-in range from cabinet opening to provide easier access to rear wall. Otherwise put a thick, protective covering over countertop, cooktop or range to protect from damage or dirt.

C

A.Centerline

B.Lower support bracket

C.Mounting height reference

D.Fastener locations

6

Page 6
Image 6
Whirlpool 19760268A Installation Instructions, Electrical Requirements, Prepare Location, Excessive Weight Hazard