Whirlpool 19760268A Make Electrical Connection, Non-vented recirculating installation

Models: 19760268A

1 28
Download 28 pages 623 b
Page 8
Image 8
Non-vented (recirculating) installation

Non-vented (recirculating) installation

1.Assemble the 3 parts of the deflector with 2 screws provided. The assembled deflector should be sized to fit the width of the vent cover bracket installed earlier.

A

B

A. Vent cover bracket width

B.Deflector

2.Connect the deflector to the vent cover bracket using 4 screws provided.

A

A. Vent cover bracket

3.Measure length of 8" (20.3 cm) vent needed to connect the transition to the deflector.

NOTE: Vent should fit up inside deflector 1" (2.5 cm) minimum.

4.Install vent between the transition and the deflector.

5.Seal all connections with duct tape.

Make Electrical Connection

Make Electrical ConnectionWARNING

Electrical Shock Hazard

Disconnect power before servicing.

Replace all parts and panels before operating.

Failure to do so can result in death or electrical shock.

1.Disconnect power.

2.Remove terminal box cover.

3.Remove the knockout.

A

B Manual background

A.Knockout

B.Terminal box cover

4.Install the UL- or CSA-listed conduit connector.

A

Manual background C

B Manual background

A.Conduit

B.Terminal box cover

C.Conduit connector

5.Run 3 wires, black, white and green (14 AWG) in ¹⁄₂" conduit from service panel to terminal box.

6.Use twist-on connectors and connect black wires together.

7.Use twist-on connectors and connect white wires together.

8

Page 8
Image 8
Whirlpool 19760268A installation instructions Make Electrical Connection, Non-vented recirculating installation