Whirlpool 3374369 Before you start, Parts supplied for installation, Electrical requirements

Models: 3374369

1 7
Download 7 pages 31 Kb
Page 2
Image 2
Before you start...

Before you start...

Proper installation

is your responsibility.

Make sure

you have everything

necessary

for correct

 

installation.

It is the

personal

responsibility

and

obligation

of

the

customer

to contact

a qualified

installer to

assure that

electrical

and plumbing

installations

 

meet

all

national

and local

codes and

 

ordinances.

 

 

 

Proper electrical, drain and water supply lines must be available or must be installed as specified within shaded area. Plumbing and wiring should not cross in front of motor or dishwasher legs. See Electrical, Water and Drain requirements.

IMPORTANT: Observe all governing codes and ordinances.

Corner location 2” min. door to cabinet or wall. -

Check location where dishwasher will be installed. The location should provide:

l Easy access to water, electricity and drainage lines,

l Convenient loading -the best position is left or right of kitchen sink.

l Opening that is square for proper dishwasher operation and appearance.

l Cabinet front that is perpendicular to floor.

l Protection so that water inlet valve and drain cannot freeze.

Electrical

ground

 

 

 

 

 

 

 

 

 

 

 

 

 

is required.

 

Cut openings

-

 

 

 

 

 

Grommet

 

See “Electrical

Water

line:

l/2”

hole or

larger.

required

for

 

requirements.

II

Drain

line:

l-1

/2”

hole

 

 

 

electrical

 

 

 

 

 

 

or larger.

 

 

 

 

 

 

 

cable

or

 

 

 

 

 

Power

supply

cord:

l-1

/2”

max.

power

supply

 

 

 

 

 

hole.

 

 

 

 

 

 

 

 

cord

hole

cut

 

power

supply

Direct

wiring:

3/4”

min.

hole.

in a

metal

 

 

 

 

 

 

 

 

 

 

cabinet.

I

I

cord

or

kink

 

 

The

unshaded

area

must

be free

 

 

 

 

 

I III

power

supply

 

Electrical

of

pipes

or

wires.

installed

 

 

34” min.

cable

between

 

 

outlet

must be

 

4”’

underside

 

 

 

in an

adjacent

cabinet.

 

counter

dishwasher

and

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

height.

cabinet.

 

(0

--------

 

 

 

 

 

i

 

--

------

 

 

o’,

dishwasher

over

 

 

 

 

 

 

 

 

 

 

 

 

 

Figure

1

p-

 

24W=ning

 

 

 

 

 

width

 

 

 

IV

24 depth -

V

23-710” width N

 

 

 

 

33-7/i!”

min. height

l l/4” minimum clearance between motor and flooring to prevent motor from overheating.

Electrical Shock Hazard

l It is the personal responsibility and obligation of the customer to contact a qualified electrician to assure that the electrical installation is adequate and is in conformance with the National Electrical Code, ANSI/NFPA 70 - latest edition’ and all local codes and ordinances.

Failure to follow these instructions could result in electrical shock or other personal injury.

l Electrical wiring and components must not contact any plumbing material or drain hose.

l Cabinet opening must completely enclose sides, top and back of dishwasher.

Failure to do so may result in personal injury from exposed wiring.

Personal Inju;;;-r.rct Damage

Avoid opening dishwasher door before dishwasher is installed. Dishwasher, before it is installed, may tip over when door is opened, resulting in personal injury or product damage.

Copies of the standards listed may be obtained from:

‘National Fire Protection Association Batterymarch Park

Figure 2

1

Quincy, Massachusetts 02269

Read and follow the “Electrical

requirements”, “Water requirements” and ‘Drain requirements” sections before installing dishwasher.

Tools and materials needed for installation:

Electrical requirements

Electrical Shock Hazard

l Electrical ground is required on this appliance.

l If cold water pipe is interrupted by plastic, non-metallic gaskets or other insulating materials, Do Not use for grounding.

. Do Not ground to a gas pipe.

lDo Not modify the power supply cord plug. If it does not fit the outlet, have a proper outlet installed by a qualified electrician.

Recommended grounding method

For your personal safety, this appliance must be grounded. This appliance is equipped with a power supply cord having a 3-prong grounding plug. To minimize possible shock hazard, the cord must be plugged into a mating,

3-prong, grounding-type wall recept-

acle, grounded in accordance with National Electrical Code, ANSI/NFPA 70

-latest edition* and all local codes and ordinances, (See Figure 3.) If a mating wall receptacle is not available, it is the personal responsibility and obligation of the customer to have a properly grounded, 3-prong, wall receptacle installed by a qualified electrician.

l electric drill

l Phillips screwdriver

l2 adjustable wrenches

lpliers

l measuring tape

lflat-blade screwdriver

l pipe wrench

l keyhole saw

l

l

l

l

l

tubing cutter (not shown)

pipe-joint compound

5116” and l/4” driver or hex socket

gloves

90” elbow with 318” N.P.T. external threads on one end. The size of the other end must fit your water supply line.

) Do Not have a fuse in the neutral or grounding circuit. A fuse in the neutral or grounding circuit could result in electrical shock.

b Do Not use an extension cord with this appliance.

BCheck with a qualified electrician if you are in doubt as to whether the appliance is properly grounded.

Failure to follow these instructions could result in serious injury or death.

If codes permit and a separate

8no P 800

cord-

Figure 3

IF POWERCORD CANNOT

BE USED...

Parts supplied for installation:

l 2 drain hose clamps

l 2, No.-1 0 x l/2” Phillips-head screws

l drain hose

Remove parts from bag. Check that all parts were supplied.

grounding wire is used, it is recommended that a qualified electrician determine that the grounding path is adequate.

A 120-volt, 60-Hz, AC-only, 15or 20- ampere, fused electrical supply is required. Time-delay fuse or circuit

breaker is recommended. It is

recommended that a separate circuit serving only this appliance be provided.

When local codes do not permit use of a power supply cord with an

undercounter dishwasher, the power supply cord must be removed and dishwasher wired directly. To direct wire this product, order kit #4317979.

Electrical connections must be contained within the terminal box and meet all local codes and ordinances.

IF THE POWER SUPPLY CORD IS REMOVED, THE DISHWASHER MUST BE CONNECTED WITH COPPER WIRE ONLY.

Panel A

Page 2
Image 2
Whirlpool 3374369 Before you start, Parts supplied for installation, Electrical requirements, If Powercord Cannot Be Used