Recessed and closet installation instructions
Recessed area minimum installation spacing
Fire Hazard
l It is recommended that the dryer be
exhausted outside
l If washer/dryer is installed in a
closet, the dryer MUST be exhausted
outside.
Failure to do so may cause a fire.
This washer/dryer may be installed in a
recessed area or closet.
The installation spacing is in inches and
is minimum allowable. Additional
spacing should be considered for ease
of installation, servicing and compliance
with local codes and ordinances.
If closet door is installed, the minimum
unobstructed air openings in top and
bottom are required. Louvered doors
with equivalent air openings are
acceptable. Closet installation must be
exhausted.
Other installations must use the minimum
dimensions indicated.
TO PREVENT LARGE AMOUNTS OF LINT
AND MOISTURE FROM ACCUMULATING,
TO MAINTAIN DRYING EFFICIENCY, THIS
APPLIANCE SHOULD BE EXHAUSTED
OUTDOORS.
a- 3”
Washer
I J
•I .
Side View Front View
Recessed, non-exhausted installation
must use only the rear exhaust position
and Exhaust Deflector Part No. 694609.
Note: If recessed installation is
exhausted to the side or rear, 6 inches
must be available above the
washer/dryer but all other spacing can
be 0 inches.
Closet installation must be exhausted outdoors.
f
48. sq. in. +*
4
1” min.+
24. sq. in.
l
*
Closet Door
/
4
6”
Side View
Closet Door
sq. in.
l
*
sq. in.
l
*
4
Front View
Additional clearances for wall, door and floor
moldings may be required or if external
exhaust elbow is used.
**
*
Opening is minimum for closet door, Louvered
door with equivalent air openings is
acceptable.
*** $MiEnal space may be needed for exhaust