Tools needed for installation:

adjustable

wrench

level

utility

knife

 

pliers

Phillips

screwdriver

duct tape

flat-blade screwdriver

Parts supplied

for

hstallation:

 

 

2

slide

protectors

8 screws

 

2

slide

extensions

2,30-minute

cams

2

bolt

and washer

2,60-minute

cams

assemblies

4,3/4” wood

screws

Parts owner must supply:

1 control panel lock and key

2 coin vaults and keys (E.S.D. vault must have projecting lock.)

2 coin-slide mechanisms (vertical 8)

Parts may be ordered from Greenwald Industries, Inc. or Equipment Systems and Devices, Inc.

l Greenwald Industries, Inc.

1340 Metropolitan Avenue Brooklyn, NY 11237 telephone (7 18) 82 l-9000 or toll free (800) 22 l-0982

fax no. (718) 417-7412

l Equipment Systems and Devices, Inc.

270 New Jersey Dr.

Fort Washington, PA 19034 telephone (2 15) 628-0860 or toll free (800) 523-1510

fax no. (2 15) 643-4623

Gas supply reauirements

a

Fire Hazard

l These dryers must be connected to a regulated gas supply.

Failure to do so could result in high- pressure gas release, resulting in a fire or explosion.

l Have L.P. gas checked by a qualified person before installing the dryer. The L.P. gas supply must not exceed a pressure of 13” water column.

l New flexible tubing should be used. Reusing old, flexible tubing might result in possible leaks or fire hazard.

Failure to follow these instructions could result in fire or explosion.

OBSERVE ALL GOVERNING CODES AND ORDINANCES.

A n This installation must conform with American National Standard, National Fuel Gas Code ANSI 2223. l- latest edition”, and all local codes and ordinances.

B n The desian of this drver has been certified bv the American Gas Association for use at altitudes up to 10,000 feet above sea level at the B.T.U. rating indicated on the model/serial plate. Burner input adjustments are not required when the dryer is operated up to this elevation.

When installed above 10,000 feet, a four percent (4%) reduction of the burner B.T.U. rating shown on the model/serial plate is required for each 1,000 foot increase in elevation. For assistance when converting to other gas types and/or installing above 10,000 feet elevation, contact your local service company.

C n Check that dryers are equipped with the correct burner for the particular type of gas used. Burner information will be found on the rating plate in door well of the appliance. If this information does not agree with the type of gas available, see your dealer.

D n These dryers are shipped for use with NATURAL GAS. They are certified by the American Gas

Association for manufactured, mixed and L.P. (propane and butane) gases

with appropriate conversion. No attempt shall be made to convert the appliance from the gas specified on the rating plate for use with a different gas without consulting the serving gas supplier. Conversion must be done by a qualified service technician. Gas conversion kit part numbers are listed on the gas valve burner base.

E n Provide a rigid gas supply line of l/2-inch IPS pipe to the dryer’s location. If the total length of the supply line is more than 20 feet, larger pipe will be needed. For L.P. gas usage, 3/8-inch, approved copper tubing may be used. Pipe-joint compounds suitable for use with L.P. gas should be used.

FH If local codes and ordinances

permit, it is recommended that new flexible metal tubing, design-certified by the American Gas Association, be used for connecting the dryers to the gas supply line. (The gas feed pipe, which extends through the lower rear of each dryer, is provided with 3/8- inch male pipe thread.)

G n The supply line shall be equipped with a shutoff valve. This valve should be located in the same room as the dryers and should be in a location that allows ease of opening and closing. Do Not block access to shutoff valve.

main gas supply line, a combination of fittings must be used to obtain an in-line connection to the dryers.

I n Make sure lower edges, back and sides of the cabinet are free of obstructions to permit adequate clearance of air openings for combustion air. See “Recessed area and closet installation instructions” for minimum spacing requirements.

J n For ease of installation, operating and servicing (if ever needed), adequate space should be provided around the dryers.

K n A l/8-inch, NPT plugged tapping, accessible for test gauge connection, must be installed immediately upstream of the gas supply connector to the dryers.

The dryers and their individual shutoff

valves must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of l/2 psig (3.4 kPa).

The dryers must be isolated from the gas supply piping system by closing their individual manual shutoff valves during any pressure testing of the gas supply piping system at test pressures equal to or less than l/2 psig

(3.4 kPa).