Remove the red caps from the gas pipes.

11.

00

8

00

8

0

14 w

Plug power supply cords into grounded outlets. Turn on electrical power supply.

16.

Check levelness of dryers by placing a carpenter’s level on top of the dryers or collar, first side to side, then front to back. If dryer is not level, adjust the front legs up or down. Make the final check with the level.

Connect gas supply to each dryer. Use pipe-joint compound resistant to the action of Natural and L.P. gas for gas connections.

12.

Open the shutoff valves in the gas supply lines.

Fire Hazard

Do Not use an open flame to test for leaks from gas connections.

Checking for leaks with a flame may result in a fire or explosion.

13.

Use a brush and liquid detergent to test all gas connections for leaks. Bubbles around connections will indicate a leak. If a leak appears, shut off gas valve controls and adjust connections. Then check connections again. NEVER TESTFOR GAS LEAKS WITH A FLAME. Close the access panels.

All connections must be wrench- tightened.

Floor Damage

Slide dryers onto cardboard or hardboard before moving across floor.

Failure to do so may result in damage to floor covering.

Move unit to its permanent location.

15.

Turn one dryer on to remove air from the gas supply line. Using a full heat cycle (not the air cycle), let the dryer run for at least five minutes, If the burner does not ignite and you can feel no heat inside the dryer, shut off the dryer for five minutes. Check that all supply valve controls are in ‘ON” position and that the power supply cord is plugged in. Repeat the five- minute test.

17 n TO exhaust the dryers, see “Exhaust requirements” and “Exhaust

duct connection,” pages 5 and 6.

Personal Injury Hazard

To prevent tipping, tether bracket must be secured to wall studs or concrete wall.

Failure to do so could result in personal injury.

Tether bracket, located at rear of the top dryer.

w

Attach both ends of tether located at the rear of the top dryer to a secured

2x4.

Page 9

Page 9
Image 9
Whirlpool 3395339 manual 14 w, Move unit to its permanent location