Recessed and closet

Recessed area minimum

installation spacing

Product dimensions

installation instructions

This washer/dryer may be installed in a recessed area or closet.

The installation spacing is in inches and is minimum allowable. Additional spacing should be considered for ease of installation, servicing and compliance with local codes and ordinances.

If closet door is installed, the minimum unobstructed air openings in top and bottom are required. Louvered doors with equivalent air openings are acceptable. Closet installation must be exhausted.

Other installations must use the minimum dimensions indicated.

0" *

side view

0" *

0" *

 

dryer

 

washer

front view

6"

Most installation will require at least 5 inch clearance behind the dryer for the dryer vent.

Location must be large enough to fully open dryer door.

26-1/4"

28"

72-3/4"

48"

5"

34-3/4"

33-1/4"

Recessed, non-exhausted installation must use only the rear exhaust position and Exhaust Deflector Part No. 694609.

Note: If recessed installation is exhausted to the side or rear, 6" must be available above the washer/dryer but all other spacing can be 0".

Closet installation must be exhausted outdoors.

WARNING - To reduce the risk of fire, this appliance MUST BE EXHAUSTED OUTDOORS.

32-1/4"

side view

27-3/8"

13-11/16"

 

 

 

 

13-11/16"

 

 

 

 

 

 

closet door

closet door

0" ***

 

3"

 

6"

 

48 sq. in. **

 

 

48 sq. in. **

 

1" min.

1-1/2" hot water inlet

24 sq. in. **

24 sq. in. **

5"

3"

 

recess

 

depth

exhaust outlet 36-3/4"

27" 28-1/2"

cold drain

water outlet inlet

front view

side view

*Additional clearances for wall, door and floor moldings may be required or if external exhaust elbow is used.

**Opening is minimum for closet door. Louvered door with equivalent air openings is acceptable.

13-1/2" recess width

22-3/4"

***Additional space may be needed for exhaust elbow.

rear view

CRUSH

Dura Safe

RESISTANT

TM

 

SURE CONNECTTM Vent Kit

Periscopes For Offset

Outlets, Tight Installations

For more information, or to easily place your order, call

Kits Make Installation Easy

Provides 4 1/2” clearance between dryer and wall

Snap-Lock fittings

Total kit length 8 feet

Provides 2 1/2” clearance between dryer and wall

Great for closet installations

0"-18", 18”-29” or 29”- 50” periscopes include one male snap-lock fitting, one extra long draw-band collar and one clamp

2 1/2"

21/2"

0"-18" : Part #4396037

18"-29" : Part #4396011

29"-50" : Part #4396014

1-800-442-9991

To have your venting

professionally installed,

call

Additional vent can be snapped between

Part #4396028sections for

longer runs

Kit Contains:

2- 4' vent sections with attached close elbows

1- Wall plate for close clearance installations

2- 4" clamps

.

Dura Safe and Sure Connect are Trademarks of Whirlpool, U.S.A.

0"-18" Periscope

Use when vent outlets overlap or are offset

Excess length can

be trimmed to fit

Part #4396037

18"-29" and 29"-50" Periscope

Sections separate,

fittings can face

Swivel collarsame or opposite wall connection

Telescoping

 

Swivel collar

sections

 

 

 

 

 

 

 

 

Extra long

Beveled edges

 

 

band-clamp

 

 

for dryer

allow corner

 

 

connection

installations

 

 

 

 

 

 

 

 

 

 

 

 

 

 

18"-29" : Part #4396011

 

 

29"-50" : Part #4396014

 

1-800-253-1301

for the nearest

authorized service

provider.