Panel G

Recessed and closet

installation instructions

This washer/dryer may be installed in arecessed area or closet.The installation spacing is in inches andis minimum allowable. Additionalspacing should be considered for easeof installation, servicing and compliancewith local codes and ordinances.If closet door is installed, the minimumunobstructed air openings in top andbottom are required. Louvered doorswith equivalent air openings areacceptable. Closet installation must beexhausted.Other installations must use the minimumdimensions indicated.
Recessed, non-exhausted installation must use only the
rear exhaust position and Exhaust Deflector Part No. 694609.
Note: If recessed installation is exhausted to the side or rear,
6" must be available above the washer/dryer but all other
spacing can be 0".

Product dimensions

*Additional clearances for wall, door and floor moldings may be required or if external exhaust
elbow is used.
**Opening is minimum for closet door. Louvered door with equivalent air openings is acceptable.
***Additional space may be needed for exhaust elbow.
6"
0" ***
dryer
washer
Closet installation must be exhausted outdoors.
closet door
side view
48 sq. in. **
24 sq. in. **
6"
1" min.
3"
3"
48 sq. in. **
front view side view
closet door
Recessed area minimuminstallation spacing
72-3/4"
5"
33-1/4"
32-1/4"
side view
24 sq. in. **
34-3/4"
28"
26-1/4"
0" *0" *
front view
48"
rear view
27-3/8"
13-11/16"
13-11/16"
1-1/2"
hot
water
inlet
13-1/2"
recess width
5"
recess
depth
27"
cold
water
inlet
exhaust
outlet
36-3/4"
28-1/2"
drain
outlet
22-3/4"
0" *
WARNING - To reduce the risk of fire, this appliance MUST BE EXHAUSTED OUTDOORS.
Most installation will require at least 5 inch
clearance behind the dryer for the dryer vent.
Location must be large enough to fully open dryer
door.
SURE CONNECTTM Vent Kit
CRUSHRESISTANT
Dura SafeTM
Kits Make Installation EasyProvides 4 1/2” clearance between dryer and wallSnap-Lock fittingsTotal kit length 8 feetAdditional vent can be snapped betweensections for longer runsKit Contains:2- 4' vent sections with attached close elbows1- Wall plate for close clearance installations2- 4" clampsPart #4396028Sections separate, fittings can facesame or oppositeExtra longband-clamp for dryer connectionSwivel collarBeveled edgesallow cornerinstallationsTelescoping sectionsSwivel collar wall connectionProvides 2 1/2” clearance between dryer and wallGreat for closetinstallations0"-18", 18”-29” or 29”- 50” periscopes include one male snap-lock fitting, one extra long draw-band collar and one clamp
2
1/2"
2
1
/
2
"
Periscopes For Offset
Outlets, Tight Installations
Use when vent outletsoverlap or are offsetExcess length can be trimmed to fit18"-29" and 29"-50" Periscope0"-18" Periscope
0"-18" : Part #4396037
18"-29" : Part #4396011
29"-50" : Part #4396014
Part #439603718"-29" : Part #4396011 29"-50" : Part #4396014
Dura Safe and Sure Connect are Trademarks of Whirlpool, U.S.A.
For more information, or to easily place yourorder, call

1-800-442-9991

To have your venting professionally installed,call

1-800-253-1301

for the nearest authorized serviceprovider..