Whirlpool 3775 service manual Cause Signal Type Frequency Remedy, Error Signals, Dymanic Soak

Models: 3775

1 21
Download 21 pages 53.63 Kb
Page 9
Image 9

soaking time is 32 minutes with the machine agitating for the first 2 minutes. This is followed by 20 seconds agitation and 3 minutes soak cycle for the remaining 30 minutes.

*ERROR SIGNALS:

During operation, if any malfunction or misoperation occurs, the timer automatically indicates the same to he user through an appropriate error signal. The various possible errors during operation and the type of error signal along with the remedies are listed in the table as below

CAUSE

SIGNAL TYPE

FREQUENCY

REMEDY

 

 

 

 

Lid is open during the spin

1”BEEP 1” OFF

EVERY 5 SECONDS

CLOSE THE LID

 

 

 

 

Improper drain /High drain

½”BEEP ½”OFF

EVERY 5 SECONDS

REMOVE DRAIN

time

½”BEEP 3 ½” OFF

TILL THE PR. SWITCH

RESTRICTIONS

 

 

RESETS

 

Course select button is

1”BEEP 1”OFF 1”BEEP

FOR EVRY PRESS OF

NO OPTIONS

pressed down whenever

1”OFF 1”BEEP 1”OFF

COURSE SELECT KEY

AVAILABLE IN

speedy program is selected

 

 

SPEEDY PROGRAM

DYMANIC SOAK

Whenever the user SOAK the wash cycle during this soaking period the machine as alternatively stirs (agitates) for some time and soaks for some time. This aids better mixing of detergent in water hereby aiding dirt removal. The total soaking time is 32 minutes with the machine agitating for the first two minutes. This is followed by 20 seconds agitation and 3 minutes soak cycle for the reaming 30 minutes.

SERVICE/DEMO ROUTINE :

To enable the CSE s in the field to test the device for its normal operations, a service routine is provided in these ET models. to activate this, switch on the machine and press all the feather touch buttons i.e., course select, program select, start/pause key and the cancel key simultaneously. Then release the cancel button. This will lead the machine o service routine wherein the following operations are performed in sequence

1.All the 8 LED’s will be lighted.

2.Valve inlet will be switched on for 10 seconds.

3.Normal Agitation for 40 Sec.

4.Slow Agitation for 40 Sec.

5.Drain will be on for 20 Sec.

6.Spin will be on for 8 seconds.

7.EOC Buzzer will be for 15 seconds.

This document is only intended for qualified technicians who are aware of the respective safety regulations.

Revised on 07/01/2003Subject to modification Document No. WOI/WM/2003/001