Whirlpool 761883306 manual ’ ‘i, l-3/8, Numbers correspond to steps

Models: 761883306

1 7
Download 7 pages 11.73 Kb
Page 4
Image 4
Numbers correspond to steps.

Injury Hazard

More than one person is required to help with installation because of the weight and size of range hood.

Failure to follow this instruction could result in serious injury.

keyhole slot

front

of hood

w

8n Lift the range hood into final position and center. Mark on the underside of cabinet the location of the four keyhole mounting slots. Set range hood aside on a protected surface.

I

9 n Determine and clearly mark a vertical centerline on the wail and cabinet in the area the vent opening will be made.

Electrical Shock Hazard

Take special care when drilling holes into the wall.

Contacting electrical wires concealed behind the wall covering could result in death or serious injury.

centerline

Numbers correspond to steps.

 

I

 

J

I

’ ‘(i

l-3/8:_._ &

_ ,

I-

 

i 7-l/r’ I

 

 

\I,

;*I;

&l-5/8” (to floor)

I

centerline t

To wire through rear, mark a line 7-l J2” from the right of the centerline on the wall. Mark the point on this line that is 64-5/8” from the floor (or l-3/8” from underside of cabinet).

Drill a l-l /4” diameter hole through wall at this point.

\

11 n TO vent through the roof with 7” round ductwork, mark 4-l 72” and 5” in from back wall along the centerline on underside of cabinet. Use these points as centers to draw 7-l J8” circles on underside of cabinet. Use a saber saw to cut the openings for the ductwork. Repeat for the underside of the top of the cabinet. This will create slotted openings.

To vent through wall with 3- l/4” x 10” rectangular ductwork, measure from floor 65-7/B” and 62-3/a” (or 1J8” and 3-5/W down from underside of cabinet) and mark on back wall. Measure and mark a line 5-l J4” to right and left of centerline, connecting the two lines. Use a saber saw to cut a rectangular opening for the ductwork.

12 n Install ductwork through the vent opening in upper cabinet or wall. Complete venting system according to method needed. See “Venting

requirements.” Use caulking to seal exterior wall or roof opening.

round

13 WAt-tach rectanaular damcer to selected rectangular vent opening. If damper is attached to back of range hood, be sure damper hinge is toward the top. For round vented installations, use round damper in duct to prevent air from flowing back into ductwork. If wall or roof cap has a damper, remove damper blade from range hood.

14 1 Run wiring through wall or cabinets according to the National Electrical Code and local codes and ordinances. Do Not turn on power until installation is complete.

keyhole slot

10 n TO wire throuah totx mark a line

7-l /2” from the right of thz centerline on the underside of the cabinet. Mark the point on this line that is l-3/8” from back wall. Drill a l-1 /4” diameter hole through the cabinet at this point.

Panel C

m screw

15 n Start screws throuah neck of each of the four keyhole mounting screw slots marked on the cabinet bottom.

To vent through the roof with 3-l /4” x 10” rectangular ductwork, mark a line 1” and 5” from the back wall on the underside of the cabinet. Mark lines 5-1 J4” to the right and left of the centerline on the underside of cabinet that connect the lines just drawn. Use a saber saw to cut a rectangular opening for the ductwork. Repeat for the underside of the top of the cabinet.

Page 4