Conversion
Converting to 1 P. gos | Natural |
should be done by
a qualified installer.
Only a qualified A installer should
.. install or
adjust your gas range. Pressure Regulator: Use a wrench to unscrew the cao from
the top by turning counter-
clockwise. Turn the cap over so the hole end is up. Replace the cap and gasket on the regulator. DO NOT REMOVE THE PRESSURE REGULATOR.
against pin. DO NOT OVERTIGHTEN.
Adjust the air shutters for proper flame by ’ sliding the air shutter to close or open the shutter as needed. See Panel C. step 19 for electrical ignition systems or Step 20A for standing pilot systems,
Cooktop burners with standing pilots require adjustment of pllot flame to l/4 high. The adjustment control is located on the manifold pipe or at pllot flame base, depending on the model.
i”, _
P Oven Burner: Remove oven
b.racks and lower panel from oven bottom. Turn the orifice hood down until snug against pin. DO NOT OVERTIGHTEN. Tne burner flame should be l/2’ long when air shutter is correctly adjusted. The air shutter slides to close or open the shutter as needed. See Panel C. Step 22 for electronic ignition systems, or Step 24A for standing pilot systems. Replace oven bottom and racks.
Standing Pilot System
(No thermostat adjustment needed for electronic ignition system.)
D. | Oven | thermostat: | Remove | |||
thermostat | knob, | pulling stiolght | ||||
off. Use a | small | screwdriver | to | rotate the | ||
key to | L.P. | Replclce | thermostat | knob. |
E After all the burners have been converted to L.P. gas usage and
gasyine is connected, check for leads. Use a brush and liquid detergent to test
all gas connectlons for leaks. Bubbles
around connections will lndlcate a leak. If a leak appears, shut off gas valve controls and
connections. Then check connectlons again. NEVER TEST FOR GAS LEAKS WITH A MATCH OR OTHER FLAME.
.i_
Prepared | by Whrlpocl | Cornorotlon. | Genton Harbc’. ISilchlgan 49022 | PrInted in U.S.A |