Page 9
Four-wire connection...Four-wire power supply cord must havefour, No.-10 copper wires and match afour-wire receptacle of NEMA Type 14-30R. The fourth wire (groundconductor) must be identified with agreen cover and the neutralconductor by a white cover.
NEUTRAL NEUTRAL (white)
3/4" U.L.-listed
strain relief
ground prong ground wire
(green)
ring terminals
spade
terminals with
upturned ends
4. Remove center terminal block screw.
4.Remove center terminal block
screw.
6. Connect ground wire (green) of
power supply cord to external
ground conductor screw. Tighten
screw.
7. Place the hooked end of the
neutral wire (white or center) of
power supply cable under the center
screw of terminal block (hook facing
right). Squeeze hook end together.
Tighten screw.
8. Place the hooked ends of the
other power supply cable wires
under the outer terminal block screws
(hook facing right). Squeeze hooked
ends together. Tighten screws.
7. Connect neutral wire (white or
center) of power supply cord under
center screw of the terminal block.
Tighten screw.
8. Connect the other wires to outer
terminal block screws. Tighten screws.
6. Connect the ground wire (bare)
of the power supply cable to theexternal ground conductor screw.Tighten screw.
9. Tighten strain relief screws.
10. Insert tab of terminal block cover
into slot of dryer rear panel. Secure
cover with hold-down screw.
9. Tighten strain relief screws.
10. Insert tab of terminal block cover
into slot of the dryer rear panel. Secure
cover with hold-down screw.
5. Remove appliance ground wire
(green with yellow stripes) from
external ground connector screw.
Fasten under center, silver-colored
terminal block screw.
5. Remove appliance ground wire
(green with yellow stripes) from
external ground connector screw.
Fasten under center, silver-colored
terminal block screw.
POWER SUPPLY CORD

DIRECT WIRE

Preparing the wire:

3/4" U.L.-
listed strain
relief
to
disconnect
box NEUTRAL wire
(white or center)
10-gauge, 3-wire
with ground wire
(Romex)
5" (12.7 cm)
3-1/2" (8.9 cm)
1" (2.5 cm)
of wires
stripped of
insulation
bare ground
wire
Strip 5" (12.7 cm) of outercovering from end ofcable. Leave bare groundwire at 5 inches. Cut 1-1/2"(3.8 cm) from 3 remainingwires. Strip insulation back 1 inch (2.5 cm).Shapeendsofwiresinto ahook.
Four-wire receptacle (required for mobile homes)