(not the air cycle), let the dryer run for at least five minutes. Dryer will stop when time is used up.
NOTE: Dryer door must be closed for dryer to operate. When door is open, dryer stops, but timer continues to run. To restart dryer, close door and push START/RESTART button.
4.If the burner does not ignite and you can feel no heat inside the dryer, shut off dryer for five minutes. Check that all supply valve controls are in “ON” position and that the electrical cord is plugged in. Repeat
5.If drying time is too long, make sure lint screen is clean.
INSTALLATION INSTRUCTIONS – ELECTRIC DRYER
Install Coin Slide and Coin Box
The console houses the
The
The coin slide mechanism, control panel lock and key, and coin box lock and key are not included and are available from usual industry sources.
WARNING
Excessive Weight Hazard
Use two or more people to move and install dryer. Failure to do so can result in back or other injury.
NOTE: Slide dryer onto cardboard or hardboard before moving to avoid damaging floor covering.
1.Using two or more people, move dryer to desired installation location.
2.Take tape off front corners of dryer. Open dryer and remove the literature and parts packages. Wipe the interior of the drum thoroughly with a damp cloth.
3.Take two of the cardboard corners from the carton and place them on the floor in back of the dryer. Firmly grasp the body of the dryer and gently lay it on its back on the cardboard corners.
4.With one of the legs in hand, check the ridges for a diamond marking. That's how far the leg is supposed to go into the hole.
5.Start to screw the leveling legs into the holes by hand. (Use a small amount of liquid detergent to lubricate the screw threads so it is easier to turn the legs.) Use a
Now stand the dryer up.
6.Remove the service door of the meter case by lifting it up at the back. Install the
7.Replace the meter case service door. Put the coin vault with lock and key in the meter case opening.
8.Remove cardboard or hardboard from under dryer.
Make Electrical Connection
Power Supply Cord Method – U.S. Only
This dryer is manufactured with the neutral ground wire connected to the neutral (center) of the wiring harness at the terminal block. If local codes do not permit this type of connection, use
Use a
WARNING
Fire Hazard
Use a new UL listed 30 amp power supply cord.
Use a UL listed strain relief.
Disconnect power before making electrical connections.
Connect neutral wire (white or center wire) to center terminal (silver).
Ground wire (green or bare wire) must be connected to green ground connector.
Connect remaining 2 supply wires to remaining 2 terminals (gold).
Securely tighten all electrical connections.
Failure to do so can result in death, fire, or electrical shock.
1.Disconnect power.
For dryers using coin slides, use the adapter kit supplied with the dryer.
11