Direct Wire Method – U.S. Only
WARNING
Fire Hazard
Use 10 gauge solid copper wire.
Use a UL listed strain relief.
Disconnect power before making electrical connections.
Connect neutral wire (white or center wire) to center terminal (silver).
Ground wire (green or bare wire) must be connected to green ground connector.
Connect remaining 2 supply wires to remaining 2 terminals (gold).
Securely tighten all electrical connections.
Failure to do so can result in death, fire, or electrical shock.
Direct wire cable must match power supply
■Flexible armored cable or nonmetallic sheathed copper cable (with ground wire), protected with flexible metallic conduit. All
■
■At least 5 ft. (1.52 m) long.
1.Disconnect power.
2.Remove
A
CD
B
A. External ground conductor screw
B.Tab
C.Terminal block cover
D.
3.Install ³⁄₄" conduit connector into the hole below the terminal block opening. Connect flexible metallic conduit and tighten connector screw. Install direct wire cable through the flexible metallic conduit.
A B
C
A. Conduit connector
B. Dryer cabinet
C. Connector screw
4.Complete installation following instructions for your type of electrical connection:
•
•
Direct Wire,
Four-wire electrical connection:
5. | Remove the center terminal block screw. |
6. | Remove the appliance neutral ground |
| wire from the external ground conductor |
B
A
C
A
to disconnect box
D
Shape ends of wires into a hook.
1" (2.5 cm) of wires stripped of insulation
B
C
5" (12.7 cm)
Strip 5" (12.7 cm) of outer covering from end of cable. Leave green or bare ground wire at 5" (12.7 cm). Cut 1¹⁄₂" (3.8 cm) from 3 remaining wires. Strip insulation back 1" (2.5 cm).
| screw. Fasten under center, silver- |
| colored terminal block screw. |
7. | Connect the ground wire (green or bare) |
| of the direct wire cable to the external |
| ground conductor screw. Tighten screw. |
8. | Place the hooked end of the neutral wire |
| (white or center) of the direct wire cable |
| under the center screw of the terminal |
| block (hook facing right). Squeeze hook |
| end together. Tighten screw. |
9. | Place the hooked ends of the other |
| direct wire cable wires under the outer |
| terminal block screws (hook facing right). |
| Squeeze hooked ends together. Tighten |
| screws. |
10. | Insert tab of the terminal block cover into |
F
E
D
A. External ground conductor screw B. Appliance neutral ground wire C. Center terminal block screw
D. Outer terminal block screws E. Neutral (center wire)
A. ³⁄₄" conduit connector B. Neutral (white or center)
C. Ground wire (green or bare)
D.
slot of the dryer rear panel. Secure cover |
with |
F. Green or bare ground wire
14