Electrical Requirements – Gas Dryer

WARNING

Electrical Shock Hazard

Plug into a grounded 3 prong outlet. Do not remove ground prong.

Do not use an adapter.

Do not use an extension cord.

Failure to follow these instructions can result in death, fire, or electrical shock.

IMPORTANT: The dryer must be electrically grounded in accordance with local codes and ordinances or, in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70, latest edition.

If codes permit and a separate ground wire is used, it is recommended that a qualified electrical installer determine that the ground path is adequate.

A copy of the above code standards can be obtained from:

National Fire Protection Association

One Batterymarch Park, Quincy, MA 02269

A 120-volt, 60-Hz, AC-only, 15- or 20-amp, fused electrical circuit is required. A time-delay fuse or circuit breaker is also recommended. It is recommended that a separate circuit serving only this dryer be provided.

Recommended Ground Method

The dryer, when installed, must be electrically grounded in accordance with local codes or, in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70, latest edition, and all local codes and ordinances.

GROUNDING INSTRUCTIONS

For a grounded, cord-connected dryer:

This dryer must be grounded. In the event of a malfunction or breakdown, grounding will reduce the risk of electric shock by providing a path of least resistance for electric current. This dryer is equipped with a cord having an equipment- grounding conductor and a grounding plug. The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances.

WARNING: Improper connection of the equipment- grounding conductor can result in a risk of electric shock. Check with a qualified electrician or service representative or personnel if you are in doubt as to whether the dryer is properly grounded. Do not modify the plug provided with the dryer: if it will not fit the outlet, have a proper outlet installed by a qualified electrician.

SAVE THESE INSTRUCTIONS

Electrical Requirements – Electric Dryer

IMPORTANT: The dryer must be electrically grounded in accordance with local codes and ordinances or, in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70, latest edition.

The National Electric Code requires a 4-wire supply connection for homes built after 1996, dryer circuits involved in remodeling after 1996, and all mobile home installations.

If codes permit and a separate ground wire is used, it is recommended that a qualified electrical installer determine that the ground path is adequate.

A copy of the above code standards can be obtained from:

National Fire Protection Association

One Batterymarch Park, Quincy, MA 02269

A four-wire or three-wire, single-phase, 120/240-volt, 60-Hz, AC-only electrical supply (or four-wire or three-wire, 120/208-volt, if specified on the model/serial rating plate) is required on a separate, 30-amp circuit, fused on both sides of the line. A time-delay fuse or circuit breaker is recommended.

A 4-wire power supply connection must be used when the appliance is installed in a location where grounding through the neutral conductor is prohibited. Grounding through the neutral is prohibited for (1) new branch-circuit installations,

(2)mobile homes, (3) recreational vehicles, and (4) areas where local codes prohibit grounding through the neutral conductor.

Recommended Ground Method

It is your responsibility to contact a qualified electrical installer to ensure that the electrical installation is adequate and in conformance with the National Electrical Code, ANSI/NFPA 70, latest edition, and all local codes and ordinances.

GROUNDING INSTRUCTIONS

For a grounded, cord-connected dryer:

This dryer must be grounded. In the event of a malfunction or breakdown, grounding will reduce the risk of electric shock by providing a path of least resistance for electric current. This dryer uses a cord having an equipment-grounding conductor and a grounding plug. The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances.

For a permanently connected dryer:

This dryer must be connected to a grounded metal, permanent wiring system, or an equipment-grounding conductor must be run with the circuit conductors and connected to the equipment-grounding terminal or lead on the dryer.

WARNING: Improper connection of the equipment- grounding conductor can result in a risk of electric shock. Check with a qualified electrician or service representative or personnel if you are in doubt as to whether the dryer is properly grounded. Do not modify the plug on the power supply cord: if it will not fit the outlet, have a proper outlet installed by a qualified electrician.

SAVE THESE INSTRUCTIONS

6

Page 6
Image 6
Whirlpool 8577213C Electrical Requirements Gas Dryer, Electrical Requirements Electric Dryer, Recommended Ground Method

8577213C specifications

The Whirlpool 8577213C is a versatile and innovative appliance that stands out in the crowded market of kitchen solutions. As a part of Whirlpool's extensive range, this model is designed to meet the demands of modern cooking while offering user-friendly features.

One of the most notable characteristics of the Whirlpool 8577213C is its efficient design. This appliance is crafted with high-quality materials, ensuring durability and longevity in daily use. Its sleek and modern aesthetic not only enhances the kitchen’s appearance but also makes cleaning a hassle-free experience. The smooth surface helps to resist stains and marks, preserving its visual appeal over time.

Functionality is at the core of the Whirlpool 8577213C. It comes equipped with an array of cooking technologies that allow users to prepare meals with precision and ease. This model features advanced cooking settings, including multiple temperature ranges and preprogrammed options that cater to various cooking needs. Whether you're roasting, baking, or broiling, this appliance delivers consistent results every time.

Another standout feature is its intuitive control panel, which simplifies the cooking process. The user interface is designed to be straightforward, making it accessible for cooks of all skill levels. With clearly labeled buttons and easy-to-read displays, users can quickly navigate through options and set their desired cooking modes.

The Whirlpool 8577213C also emphasizes energy efficiency, adhering to ecological standards while delivering powerful performance. It is engineered to minimize energy consumption, making it an environmentally friendly choice without compromising cooking quality. This model not only saves on utility bills but also aligns with the increasing consumer demand for sustainable appliances.

In addition to its technical features, safety is prioritized in the Whirlpool 8577213C design. It includes safety lock functions and automatic shut-off settings. These features provide peace of mind while cooking, knowing that the appliance will operate safely even during busy kitchen routines.

In summary, the Whirlpool 8577213C represents the perfect blend of style, efficiency, and advanced technology. With its durable construction, user-friendly interface, energy-saving capabilities, and safety features, it is an essential tool for any modern kitchen. Whether you're a novice cook or a seasoned chef, this appliance enhances the culinary experience, streamlining the process and maximizing creativity in the kitchen.