5. Tighten strain relief nut.

1.Loosen or remove center terminal block screw.

2.Place the hooked end of the neutral wire (white or center wire) of power supply cable under the center screw of terminal block (hook facing right). Squeeze hooked end together. Tighten screw.

3.Place the hooked ends of the other power supply cable wires under the outer terminal block screws (hooks facing right). Squeeze hooked ends together. Tighten screws.

B Plan Vent System

4. Replace the terminal block cover on the back of the dryer.

A

5. Tighten strain relief nut.

 

A. Neutral wire (white or center wire)

B. Center terminal block screw

Plan Vent System

Choose your exhaust installation typeWARNING

Fire Hazard

Use a heavy metal vent.

Do not use a plastic vent.

Do not use a metal foil vent.

Failure to follow these instructions can result in death or fire.

Choose your exhaust installation type

Recommended exhaust installations

Typical installations vent the dryer from the rear of the dryer.

Alternate installations for close clearances

Venting systems come in many varieties. Select the type best for your installation. A close-clearance installation is shown below. Refer to the manufacturer’s instructions.

Over-the-top installation (also available with one offset elbow)

Over-the-Top Installation Kit Part Number 4396028 for close clearance alternate installation is available for purchase. For ordering information see “Assistance or Service.”

Special provisions for mobile home installations

The exhaust vent must be securely fastened to a noncombustible portion of the mobile home structure and must not terminate beneath the mobile home. Terminate the exhaust vent outside.

A

B Recommended exhaust installations

Alternate installations for close clearancesC

A. Exhaust hood

B. Flexible metal vent or rigid metal vent C. Elbow