Whirlpool 9762035A Electrical Connection - U.S.A. Only, Optional Rear Spacer Cover, Direct Wire

Models: 9762035A

1 24
Download 24 pages 37.94 Kb
Page 9
Image 9
Electrical Connection - U.S.A. Only

7.Align anti-tip bracket holes with holes in floor. Fasten anti-tip bracket with screws provided.

Depending on the thickness of your flooring, longer screws may be necessary to anchor the bracket to the subfloor. Longer screws are available from your local hardware store.

8.Move range close enough to opening to allow for electrical connections to be made. Remove shipping base, cardboard or hardboard from under range.

9.Make electrical connections as described in the “Electrical Connection” section.

10.Move range into its final location making sure rear leveling leg slides into anti-tip bracket.

Electrical Connection - U.S.A. Only

Power Supply Cord

Power Supply CordWARNING

Electrical Shock Hazard

Disconnect power before servicing.

Use a new 40 amp power supply cord.

Plug into a grounded outlet.

Failure to follow these instructions can result in death, fire, or electrical shock.

Direct Wire

11.If installing the range in a mobile home, you must secure the range to the floor. Any method of securing the range is adequate as long as it conforms to the standards in the “Location Requirements” section.

12.Continue installing your range using the following installation instructions.

Optional Rear Spacer Cover

(for Slide-in Ranges Only)

If you are installing a slide-in range into an existing freestanding range opening, you may use the rear spacer cover to fill in the opening at rear of range. To order, see the “Assistance or Service” section of the Use and Care Guide or contact the dealer from whom you purchased the range.

Using the screws provided with the kit, attach the rear spacer cover to the sides of the range.

Electrical Shock HazardWARNING

Electrical Shock Hazard

Disconnect power before servicing.

Use 8 gauge copper or 6 gauge aluminum wire.

Electrically ground range.

Failure to follow these instructions can result in death, fire, or electrical shock.

1.Disconnect power.

2.Remove the terminal block cover screws located on the back of the range. Pull cover down and toward you to remove cover.

A

B

A.Hold-down screws

B.Terminal block cover

9

Page 9
Image 9
Whirlpool 9762035A Electrical Connection - U.S.A. Only, Optional Rear Spacer Cover, Power Supply Cord, Direct Wire