Whirlpool 9762035A Direct Wire Installation Copper or Aluminum Wire, wire Connection Direct Wire

Models: 9762035A

1 24
Download 24 pages 37.94 Kb
Page 12
Image 12
Direct Wire Installation: Copper or Aluminum Wire

Direct Wire Installation: Copper or Aluminum Wire

This range may be connected directly to the fuse disconnect or circuit breaker box. Depending on your electrical supply, make the required 3-wire or 4-wire connection.

1.Strip outer covering back 3" (7.6 cm) to expose wires. Strip the insulation back 1" (2.5 cm) from the end of each wire.

1"

(2.5 cm)

3"

(7.6 cm)

2.Allow enough slack in the wire to easily attach the wiring terminal block.

3.Complete electrical connection according to your type of electrical supply (4-wire or 3-wire connection).

4-wire Connection: Direct Wire

Use this method for:

New branch-circuit installations (1996 NEC)

Mobile homes

Recreational vehicles

In an area where local codes prohibit grounding through the neutral

1.Remove the ground-link screw from the range frame. Save the ground-link screw and cup washer. Bend the ground-link away from the range so that it does not contact the range.

4-wire Connection: Direct WireD C

B

A

A.Ground-link screw

B.Cup washer

C.Ground-link bent away from range

2.Connect the bare ground wire to the range using the ground- link screw and cup washer. The ground wire must be attached first and must not contact any other terminal.

D

C

E

F

B

AG

A. Bare wire from power supply

E. Line 2

cable

F. Neutral (white) wire

B. Line 1

G. UL listed conduit connector

C. Hex washer head screw

and power supply cable

D. Silver-colored terminal block

 

screw

 

3.Loosen (do not remove) the hex washer head screw and insert the neutral (white) wire under the screw clamp at the bottom of the center position terminal connector.

4.Insert the other 2 wires (lines 1 and 2) under the other 2 screw clamps.

B

AManual background

A.Insert wire under screw clamp.

B.Hex washer head screw

5.Securely tighten the hex washer head screws to

35 lbs-in. (4.0 N-m) minimum torque to make proper electrical connection.

6.Tighten the locking ring of the conduit connector.

7.Replace the terminal block cover.

12

Page 12
Image 12
Whirlpool 9762035A Direct Wire Installation Copper or Aluminum Wire, wire Connection Direct Wire, D C E F B Ag, C B A